4OM-1733
1-4-10
4.3 Component Recognition Camera Section
NOTICE
Donotputyourhandontotheducialmarkblock.
Iftoomuchforceisgiventotheducialmarkblockit
may become deformed.
Fiducial Mark Block
Component Recognition Camera
(4 locations)
Every Day Cleaning
Required Time: 4 minutes
Fig. 4A4-11
Standard Condition
Condition where the Nozzle Stocker for Middle Size Odd Shaped Nozzle (Option),
and Rejected Component Box (Option) have been mounted onto the system
Component Storage Box
Every Day Cleaning
Required Time: 1 minute
Fiducial Marks (4 locations)
Every Week Cleaning
Required Time: 2 minutes
Fig. 4A4-12
Note
These options are selected together with the high-speed head SIGMA-F8
(HL) as a factory set when the system is delivered from the factor.
1403-005
4.3 Component Recognition Camera Section
4OM-1733
1-4-11
4.3.1 Component Recognition Camera Cleaning
Cycle : Every Day (Required Time : 4 minutes)
Fiducial Mark Block
Component Recognition
Camera (4 locations)
Fig. 4A4-13
Procedure
(1) Remove any dropped component, etc., using the vacuum tweezers.
(2) Wipe any dust off using the lens cleaner cloth.
Note
G -S047-01 Adhesive Cleaner (Part No: 226J2091) is also available as an option
Adhesive Cleaner
Fig. 4A4-14
Notice
Use a suction force such as a vacuum cleaner for the cleaning.
Do not blow air to any cleaning section with an air gun.
When air is blown, the dirt and dust inside the machine will disperse,
causing the recognition system and the machine to malfunction.
1403-005
4.3 Component Recognition Camera Section
4OM-1733
1-4-12
4.3.2 Rejected Component Box Cleaning
Cycle : Every Day (Required Time: 1 minute)
Fiducial Mark Block
Component Storage Box
Standard Condition Condition where the Nozzle Stocker for
Middle Size Odd Shaped Nozzle (Option),
and Rejected Component Box (Option)
have been mounted onto the system
Fig. 4A4-15
Procedure
Remove components collected in the box.
NOTICE
Before removing the accumulated components from
the box, eliminate the static electricity from your
body.
Otherwise, some components may be damaged due
to static electricity.
Notice
Use a suction force (of a vacuum cleaner) for the cleaning.
Do not blow air to any cleaning section with an air gun.
When the air is blown, dirt or dust inside the machine will disperse,
causing a malfunction in the recognition or machine operation.
1403-005
4.3 Component Recognition Camera Section