4OM-1733-005w_F8.pdf - 第98页

4OM-1733 1-4-25 NOTICE When the air-blowing is to be performed to the nozzle, make sure to start it from the nozzle end section. If the air-blowing is started from the clamp claw section, the clamp claw might be damaged.…

100%1 / 153
4OM-1733
1-4-24
Vacuum Filters (15 locations)
Every 3 Months Replacement
Required Time: 30 minutes
Nozzle Change Cam Face (Upper Side)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Center Spline
Every 3 Months Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 4 minutes
Cam Followers
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Fig. 4A4-31
1403-005
4.7 Head Section
4OM-1733
1-4-25
NOTICE
When the air-blowing is to be performed to the nozzle,
make sure to start it from the nozzle end section.
If the air-blowing is started from the clamp claw section, the
clamp claw might be damaged.
Vacuum Nozzle
Every 3 Months Inspection
Vacuum Nozzle
Every Week Cleaning
Air Blowing from the Tip
Clamp Claw
Nozzle Filter
Every Week Change
Fig. 4A4-32
Reference
Refer to "5. Vacuum Nozzle Cleaning Procedure" for the vacuum nozzle
cleaning.
1211-002
4.7 Head Section
4OM-1733
1-4-26
4.7.1 Nozzle Up/Down Ball Screw (NL-axis) Cleaning and Oiling
Cycle : Every 3 Months (Required Time : 10 minutes)
Grease : DAPHNE EPONEX GREASE No.1
Nozzle U/D Ball Screw
(NL Axis)
Fig. 4A4-33
Procedure
(1) Wipe old grease out using a rag.
(2) Apply grease in the ball screw groove slightly using the syringe.
Note
Use No. 19 (brown) nozzle.
No.19
Fig. 4A4-34
1211-002
4.7 Head Section