3.22.3 Frequency Converter Parameter Default Values VXP+
Tab. 3-7 Frequency Converter Parameter (default values)
They are mounted optionally as 7 frequency converters, the numbers of fre-
quency converters have to be allocated to the appropriate system areas.
The settings of the frequencies of each area remain default values.
Frequency
Converter No.
Function Frequency Activ
1 Preheating on top (zone 1-8) 40 Hz Yes
2 Preheating down (zone 1-8) 45 Hz Yes
3 Peak on top (Peak zone 1-3) 40 Hz Yes
4 Peak down (Peak zone 1-3) 45 Hz Yes
5 Cooling Zone 1 35 Hz Yes
6 Cooling Zone on top (Cooling Zone 2-
4)
40 Hz Yes
7 Vacuumchamber 20-25 Hz Yes
8 Option No
9 Option No
10 Option No
11 Option No
12 Option No
13 Option No
14 Option No
15 Option No
16 Option No
Vision XP+ VAC Page 127
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.4 Fans Monitoring Default Values
Fig. 3-33 Fans Parameter (example)
Tab. 3-8 Fans Monitoring (default values)
They are mounted optionally as 7 frequency converters, the numbers of fre-
quency converters have to be allocated to the appropriate system areas.
Fans Position
Entry Frequency Converter No.
Preheating on top (zone 1-8) 1
Preheating down (zone 1-8) 2
Peak on top (Peak zone 1-3) 3
Peak down (Peak zone 1-3) 4
Cooling Zone 1 5
Cooling Zone on top (Cooling Zone 2-4) 6
Page 128 Vision XP+ VAC
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.5 Interface Default Values
Tab. 3-9 Interface (default values)
3.22.6 Conveyor Default Values
Rel +/-“ 0,04 in for the PCB-width, CBS-position1 and 2
„Rel +“ 0,4 in and „Rel -“ 0,4 in, „Ymax“ 100 % for the speed
Operating state is MANUELL
Type
Entry Field Value
Interface Lane 1 Conveyor Length Impulses according to the
conveyor length
PCB delay 2 Pulses
PCB ignoring of holes 5 Pulses
Arrive Duration 20 Pulses
Given Duration 2 Pulses
PCB jam lane 1 50 Pulses
Buffer Conveyor empty 100 Pulses
Interface Lane 2 Conveyor Length Impulses according to the
conveyor length
PCB delay 2 Pulses
PCB ignoring of holes 5 Pulses
Arrive Duration 20 Pulses
Given Duration 2 Pulses
PCB jam lane 1 50 Pulses
Buffer Conveyor empty 100 Pulses