3.22.5 Interface Default Values
Tab. 3-9 Interface (default values)
3.22.6 Conveyor Default Values
Rel +/-“ 0,04 in for the PCB-width, CBS-position1 and 2
„Rel +“ 0,4 in and „Rel -“ 0,4 in, „Ymax“ 100 % for the speed
Operating state is MANUELL
Type
Entry Field Value
Interface Lane 1 Conveyor Length Impulses according to the
conveyor length
PCB delay 2 Pulses
PCB ignoring of holes 5 Pulses
Arrive Duration 20 Pulses
Given Duration 2 Pulses
PCB jam lane 1 50 Pulses
Buffer Conveyor empty 100 Pulses
Interface Lane 2 Conveyor Length Impulses according to the
conveyor length
PCB delay 2 Pulses
PCB ignoring of holes 5 Pulses
Arrive Duration 20 Pulses
Given Duration 2 Pulses
PCB jam lane 1 50 Pulses
Buffer Conveyor empty 100 Pulses
Vision XP+ VAC Page 129
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.7 Conveyor Drive Parameter Default Values
Tab. 3-10 Conveyor Drive Parameter (default values)
3.22.8 Chain Lubricator Default Values
Tab. 3-11 Chain Lubricator (default values)
Type
Definition Software
Lane 1
Speed
Pulses 100
in / mm 26,6 / 675
Max 2300
Filter 10
CCS 10
Offset Min -500
Offset Max 500
Lane 2
Speed
Pulses 100
in / mm 26,6 / 675
Max 2300
Filter 10
CCS 10
Offset Min -500
Offset Max 500
Type
Entry Field Value VAC
Conveyor Duration set value 150 Pulses 150 Pulses
Pause set value 10000 Pulses 10000 Pulses
Impulse duration 4 s 4 s
Impulse pause 60 Pulses 60 Pulses
Center Support
(option)
Duration set value 150 Pulses 150 Pulses
Pause set value 10000 Pulses 10000 Pulses
Impulse duration 4 s 4 s
Impulse pause 60 Pulses 60 Pulses
Outlet 300000 Pulses
Page 130 Vision XP+ VAC
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.9 Default Values Nitrogen control
B&R Control
Tab. 3-12 Default Values Nitrogen control
S7 Control
Tab. 3-13 Default Values Nitrogen control
Nitrogen control Value
ta
20
kp
3000
tu
25
TV
100
Typ
0
Application
0
Offset
0
Hysteresis
0
Base level factor
224
Nitrogen control Value
ta
1
kp
40
tu
30
TV
16
Typ
2
Base level factor
224