ServiceInstruction_Vision XP.pdf - 第135页
Vision XP+ V AC Page 131 3 Setup Instructions 3.22 Default V alues Operating Instructions V ersion 1.5 3.22.10 Default V alues Consumption Par ameters T ab. 3-14 De fault V al ue Consu mption P arameter s 3.22.1 1 Defaul…

Page 130 Vision XP+ VAC
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.9 Default Values Nitrogen control
B&R Control
Tab. 3-12 Default Values Nitrogen control
S7 Control
Tab. 3-13 Default Values Nitrogen control
Nitrogen control Value
ta
20
kp
3000
tu
25
TV
100
Typ
0
Application
0
Offset
0
Hysteresis
0
Base level factor
224
Nitrogen control Value
ta
1
kp
40
tu
30
TV
16
Typ
2
Base level factor
224

Vision XP+ VAC Page 131
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5
3.22.10 Default Values Consumption Parameters
Tab. 3-14 Default Value Consumption Parameters
3.22.11 Default Values Filter F9 Parameter
Tab. 3-15 Default Values Filter F9 Parameter
Consumption Parameters Value
Converter proportion of power
30
Pulses per kWh
10000
Analog Value Minimal Value
300 digits
Real Minimal Value
0 l/min
Analog Value Maximum Value
32700 digits
Real Maximum Value
1000 l/min
N² Consumption limit max.
50 m³/h
Filter F9 Parameter Value
Analog Value Minimal Value
50 digits
Real Minimal Value
0 Pa
Analog Value Maximal Value
32760 digits
Real Maximal Value
250 Pa
Limit max. 1
120 Pa
Limit max. 2
140 Pa
Measuring Frequency
40 Hz

Page 132 Vision XP+ VAC
3 Setup Instructions
3.22 Default Values
Operating Instructions
Version 1.5