ServiceInstruction_Vision XP.pdf - 第16页

Page 12 Vision XP+ V AC 2 M aintenance 2.3 Maintenance Sc hedule Operating Instructions V ersion 1.5 Cooling zone 1 (VXP) Cleaning cooling zone 1 x 1 min If neces- sary 2 min Inlet Inspection of inle t filter , clea ning…

100%1 / 142
Vision XP+ VAC Page 11
2 Maintenance
2.3 Maintenance Schedule
Operating Instructions
Version 1.5
Cleaning / lubrica-
tion PCB and CBS
spindles at the in-
let and the outlet
as well as the
oven station
x 1 min. 1 h. Oven
cleaner,
Chain oil
Check spindle nut
for „clearance“
+/- ~ 5°
x 1 min.
Nozzle holder
(VXP+)
Clean blocked
holes
Oven cleaner
x 1 min. 5 min Oven
cleaner
Trapped heat
cooler (VXP+)
Remove dust from
cooler
x 1 min. 5 min Vacuum
cleaner
Vacuum cham-
ber
Checking Sensors x 1 min. Sensors
to lubricate trans-
port
x 1 min. 5 min. Lubricant
Spindles, chain,
lifting mechanism
x 1 min. 1 min. Vacuum
grease,
Vacuum
spray,Chai
n oil
Check seal x 1 min.
Vacuum pump Check the fill level x 1 min. 1 min Fomblin
Pump station,
maintenance acc.
to manufacturer
x 1 min. For further information see the
manufacturer´s description
Cooling tract /
Condensate trap
Cleaning of cooler
/agglomerator
x 2 min If neces-
sary
2 min Cooler /
agglomera-
tor
Cleaning of fan im-
pellers
x 1 min If neces-
sary 10
min
10 min Fan Impel-
ler
Replacement of
fine filter as the
need arises
x 2 min 5 min Fine filter
EC gas blower
(VXP, VXP+
VXP+ VAC)
Clean blower, re-
place if necessary
x 5 min. If neces-
sary
10
min.
Blower
Sector Maintenance task
(inspection, cleaning
and replacement of
parts if necessary)
Daily
Weekly
Fortnightly
Monthly
Quarterly
Semiannually
Annually
Inspection Time
Maintenance Time
Replacement
Recommend-
ed Parts and
Materials
Page 12 Vision XP+ VAC
2 Maintenance
2.3 Maintenance Schedule
Operating Instructions
Version 1.5
Cooling zone 1
(VXP)
Cleaning cooling
zone 1
x 1 min If neces-
sary
2 min
Inlet Inspection of inlet
filter, cleaning if
necessary
x 1 min If neces-
sary
2 min
Check Sensor and
cleaning if neces-
sary
x 1 min If neces-
sary
2 min
Inlet exhaust Inspection of con-
tainer, connecting
pieces and throttle
cleaning if neces-
sary
x 1 min If neces-
sary 5
min
Outlet Inspection of out-
let filter, cleaning if
necessary
x 1 min If neces-
sary
2 min
Outlet exhaust Inspection of con-
tainer, connecting
pieces and throttle
valve cleaning if
necessary
x 1 min If neces-
sary 5
min
Pyrolysis Replacement of
granulate, seals
x 2 h Granulate,
seals
Gas take-off
point
Cleaning of gas
take-off point
x 1 min 5 min Hex key,
Cleaning
rag
Analyzer Pre-filter ex-
change
x indi-
cated
5 min Activated
carbon filter
Activated carbon
exchange
x indi-
cated
5 min Activated
carbon
Conveyor sys-
tem
Inspection of
chain oil fill level
x 1 min 2 min Chain oil
Inspection of
chain tension
x 10
min
30 min
if neces-
sary
Chain oil
Sensors checking x 1 min 2 min
water tank Inspection of wa-
ter tank fill level if
necessary refill
x 1 min If neces-
sary 3
min
water, anti-
freeze
Sector Maintenance task
(inspection, cleaning
and replacement of
parts if necessary)
Daily
Weekly
Fortnightly
Monthly
Quarterly
Semiannually
Annually
Inspection Time
Maintenance Time
Replacement
Recommend-
ed Parts and
Materials
Vision XP+ VAC Page 13
2 Maintenance
2.3 Maintenance Schedule
Operating Instructions
Version 1.5
Tab. 2-1 Maintenance Schedule Nitro
Control cabinets Vacuuming and
cleaning
x 10 min Vacuum
cleaner
Fan covers Vacuuming and
cleaning
x 2 min 5 min Vacuum
cleaner
Complete sys-
tem
Electrical safety
check by safety
specialist
x 2 h
Complete mainte-
nance check by
Rehm Thermal
Systems
x 8 h Due to wear
Sector Maintenance task
(inspection, cleaning
and replacement of
parts if necessary)
Daily
Weekly
Fortnightly
Monthly
Quarterly
Semiannually
Annually
Inspection Time
Maintenance Time
Replacement
Recommend-
ed Parts and
Materials