HS50_advance_level 1_20200522_221201 (1).pdf - 第166页

06/2002 E dition Studen t Guide H S-50 Advance d I 5 DLM1 C&P H ead 74 5 5 5. 4.12 .5 Set ti ngs ➠ Close the protective cover . ➠ Check that you have removed all tools and equipment from inside the placem ent system.…

100%1 / 567
Student Guide HS-50 Advanced I 06/2002 Edition
5 DLM1 C&P Head
73
Check that the plugs of the 40-pin ribbon cables between the intermediate distribution board
and head board are correctly assigned:
Make sure that the cables are not damaged and that there is no strain on the connecting
cables.
Refer to Fig. 5.4 - 29 and Table 5.4 - 5 for connecting the compressed air hoses.
5
Fig. 5.4 - 29 Connection diagram for the compressed air hoses on the collect&place head
Cable Head board Intermediate distribution board
00333491-W1 X14 X1
00333491-W2 X13 X2
Tab. 5.4 - 4 Plug-in connections for the flat ribbon cables on the head board
06/2002 Edition Student Guide HS-50 Advanced I
5 DLM1 C&P Head
74
5
5
5.4.12.5 Settings
Close the protective cover.
Check that you have removed all tools and equipment from inside the placement system.
Start the placement system.
Use the SITEST program to calibrate the collect&place head.
Fig. 5.4 - 30 Connection positions for vacuum generator on DLM1-12 head for machines HS50 and HS55
Compressed air hose no. Connection
1 Not connected
2 + 5 Via Y-shaped connecting piece to holding circuit (Y)
3 Placement circuit
4 Forced air unit
6 + 7 Holding circuit
Tab. 5.4 - 5 Connection diagram for the compressed air hoses on the collect&place head
Student Guide HS-50 Advanced I 06/2002 Edition
5 DLM1 C&P Head
75
5.4.13 Removal of DP station
5.4.13.1 Tools and equipment
Set of DIN 911 Allen keys
SITEST program
5.4.13.2 Parts
Turning station / DLM1, item no. 00341780-01 5
5.4.13.3 Dismantling the DP station
Switch the placement system off and secure it to prevent switching on again as described in
section 5.4.1
, page - 32.
Remove the plugs from sockets X12 and X18 on the head board.
5
Fig. 5.4 - 31 Plug-in connections of the turning station on the head board
Push the collect&place head until it reaches the stopper on the deflection roller of the X-axis
toothed belt.
Undo the M3x25 hexagon socket-head screw (see item 2 in Fig. 5.4 - 32) on the rear panel of
the back part.
Carefully pull the turning station (item 1 in Fig. 5.4 - 32) back and remove.