Typ 0 Vak-Test nicht aktiv, n: Anzahl BE/Segment Bewertung minimaler Vakuumabstand Maximale Toleranz ZU- Werte A nzahl der BE pro Segment A nzahl Fehler pro Segment Vakuumwert Haltekreis minimaler Vakuumwert Segment zu V…

Typ
Pipetten
typ
Kantenlänge
Meßfenster
Größe der
Verschmutzung in
um*um
Korrektur der
Schwellwerte
Stillstand bei
Fehler
Separato
r
44 44 44 44 58
Unbenutz
t
901 1700 66000 0 1
Unbenutz
t
902 1100 16000 0 1
Unbenutz
t
904 2000 160000 0 1
Unbenutz
t
906 1000 16000 0 1
Unbenutz
t
911 1700 66000 0 1
Unbenutz
t
914 2000 160000 0 1
Unbenutz
t
925 1000 66000 0 1
Unbenutz
t
926 1000 16000 0 1
this "unbenutzt"
unused refer
only to this
"typ"e column
nozzle
type
length of the
squared
measuring
window
area of polution in
µm² (all this 5
values are to edit
in DB-Editor)
correction factor
of thresholds
(always 0)
machine STOP at
scanning error
message; 0 mean
machine do NOT stop.
At 1 machine stop .
Other nozzle
types can be
added to this
list by DB-
Edit
Edition 1.0 1 scanning.xlsnozzle parameter SD EA 1 S GC Training

Typ
0 Vak-Test nicht
aktiv, n: Anzahl
BE/Segment
Bewertung
minimaler
Vakuumabstand
Maximale
Toleranz ZU-
Werte
A
nzahl der
BE pro
Segment
A
nzahl
Fehler pro
Segment
Vakuumwert
Haltekreis
minimaler
Vakuumwert
Segment zu
Vakuum
grenze
Abh/Bst
Minimaler
Blasdruck
Maximaler
Blasdruck
comment
column
Separato
r
44 44 44 44 44 44 44 44 44 62
5 350 1000 50 350 10 500 700 50 200 10000
12nozzle
C&P
6 350 1000 50 350 10 500 700 50 200 10000
6noz. C&P
7 0 1000 50 0 10 500 700 50 200 10000
not used
comment
line
C&P-head
type / 5
is 12 noz.
C&P-head
/ 6 is 6 noz.
C&P-head
/ 7 is P&P-
head
After this number of
comp. Per segment
(at the end of PCB-
placement) machine
repeat the vacuum
check. "Vacuum
distance open closed
to low"
multiplication factor
for application in
extreme altitude
above sea level.
following parameter
set:
0 to 1000 m 1000
(mean 1000 E-3)
1000 to 2000 m 800
(mean 800 E-3)
2000 m to 2500 m
700 (mean 700 E-3)
max. Vacuum-
tolerance of all
segments at
closed piston
(old 30 mbar) (1)
As soon as 10
errors have
occured at any
segment within
the above
interval (350) an
error message
("segment not
seald") will be
sent to the
station monitor.
min. Vacuum
value (mBar) at
holding circuit
min. Vacuum
value for
vacuum at
closed piston (at
altitude 1000 m
above sea level
this is reduced
to 600 )
difference in %
between nozzle
open and
Vac.threshold. If
less than 50 %
the machine
repick the comp.
imedeately.Time
optimized pick up
process!! 0 here
mean run always
to reject box.
Minimum air
kiss in mBar at
placement
(not used at the
moment in 1/10
mBar)
(1)
Counting process for
this test. The errors
are counted within an
interval of 350
placement positions.
As soon as any
segment has placed
350 components all
collected errors are
reset to 0 and the
counting process is
started again. If this
value is less than
"Fehler pro Segment"
this test is disabled.
measuring value Vacuum closed
measuring value Vacuum open
Vacuum threshold comp. correct on nozzle
Vacuum distance
open <> closed = 100%
( and more than the
min. in IDEAL.MA)
-700mbar
-1000 mbar
environment
pressure
200mbar
min. threshold nozzle closed
min. air kiss
"Vakuumgrenze Abh/Bst"
move to reject and pick up again
repeat pick upcomp. not correct
on nozzle
comp. correct picked
t
Edition 1.0 1 Vacuum_airkiss_para.xls Vacuum SD EA 1 S GC Training

Typ Pipettentyp Vacuum top position ON with nozzle for:
Separato
r
35
Pipette 911
(0402) 1*0.5 mm components,
Pipette 901
(0402) 1*0.5 mm components,
Pipette 925
(0201) 0.5*0.25 mm components,
Pipette 902
(0201) 0.5*0.25 mm components,
Pipette 906
(0201) 0.5*0.25 mm components,
Pipette 904
(0603) 1.5*.75 mm components
comment line
This are the nozzle types the vacuum is
activated ot pickup at light barrier top
position.
...with Station SW 4XX/501/502. 503 SW
program this vacuum mode at package form file.
Edition 1.0 1 Vacuum_Z.xls VAC_TOP_ON SD EA 1 S GC Training