00198150-02_SM_TX_en.pdf - 第100页
6 Gantries 6.3 Trailing Cable and Printed Circuit Boards 100 Service Manual SIPLACE TX Series 06/2017 Removal ► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized reactivati…

6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
Service Manual SIPLACE TX Series 06/2017 99
6.3.4 Replacing the Gantry Interface
Parts, Equipment and Tools
●
Gantry interface 1 [03116149‑xx]
●
Gantry interface 2 [03116147‑xx]
Overview
Fig.112: Gantry interface
1. Gantry interface
2. Trailing cable holder on gantry
Fig.113: Gantry interface
Gantry interface [03116149-xx]
1. Six fastening screws
NOTICE!
Inversely Layout
The layout of the two gantry interfaces is the
same, but inversely.
.

6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
100 Service Manual SIPLACE TX Series 06/2017
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
For a better access to the gantry interface you may remove the upper cover:
Fig.114: Removing the upper cover
► Remove the four nuts at(2) and the four nuts
at(3) on location1. Repeat for location2.
Ask for the help of a second person for the next step.
► Lift up the cover(1).
► Unplug all electrical connections to the gantry interface. You may want to mark the positions
of these connections to make clear assignment easier later on.
► Remove the six screws fastening the gantry interface and remove the gantry interface from
the machine.
Installation
► Follow the removal instructions in reverse order for installation.

6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
Service Manual SIPLACE TX Series 06/2017 101
6.3.4.1 Gantry Interface 1/2
Fig.115: Gantry interface [03116147-xx] – Gantry 1
Fig.116: Gantry interface [03116149-xx] – Gantry 2
Connectors [03116147-xx] [03116149-xx]
Connector Description
X1/X2 Power Y motor flat ribbon cable
X3 Power X motor flat ribbon cable
X4/X8 150V / 40V
X5/X9 Power fail, FDB Bus MCAN,X temperature sensor
X6/X10 GigE
X7 Power X motor track signals X axis
X11 Track signals Y axis
X12 Power Y motor
X13 Temperature sensor