00198150-02_SM_TX_en.pdf - 第232页
9 Nozzle Changers and Nozzle Stations 9.4 Replacing the Control Board Cable NC Valve [00334212-xx] 232 Service Manual SIPLACE TX Series 06/2017

9 Nozzle Changers and Nozzle Stations
9.4 Replacing the Control Board Cable NC Valve [00334212-xx]
Service Manual SIPLACE TX Series 06/2017 231
9.4 Replacing the Control Board Cable NC Valve
[00334212-xx]
Parts, equipment and tools
●
Control board cable for NC valve [00334212-xx]
Overview
Fig.310: Control board cable
1. Nozzle changer
2. Control board cable for NC valve
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Remove the nozzle changer from the machine (see 9.2 "Replacing the Nozzle
Changer" [}227]).
► Unplug the connectors on the cable at both ends and remove the cable. You may also need to
remove cable ties.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
► Replace any opened cable ties.

9 Nozzle Changers and Nozzle Stations
9.4 Replacing the Control Board Cable NC Valve [00334212-xx]
232 Service Manual SIPLACE TX Series 06/2017

10 COT Insert
10.1 COT Insert - Overview
Service Manual SIPLACE TX Series 06/2017 233
10 COT Insert
DANGER
Observe User Manual
► Please observe the safety instructions in the user manual for all work!
10.1 COT Insert - Overview
Fig.311: COT insert overview
1. Nozzle station (standard)
2. Empty tape duct
10.6 "Replacing the Empty Tape Duct Assembly
[03052576-xx]" [}244]
3. Safety switch for the component trolley
4. Feeder unlocking device
10.4 "Replacing the 40-Fold Feeder Unlocking
Device [03011582-xx]" [}239]
5. Cutter
6. Waste tape chute
7. Feeder control unit (FCU)
10.5 "Replacing the Feeder Control Unit
(FCU)" [}241]
8. Assembly positions for the nozzle changers
9. Reject bin with nozzle station (optional)
10. Component deposit – reject plate (option)
10.7 "Replacing Component Deposit