2 Basic Machine 2.5 Replacing the Machine Feet [03120976-xx] Service Manual SIPLACE TX Series 06/2017 31 2.5 Replacing the Machine Feet [03120976-xx] Parts, equipment and tools ● Machine foot D 90mm [03120976-xx] ● Opera…

2 Basic Machine
2.4 Replacing the Cover
30 Service Manual SIPLACE TX Series 06/2017
2.4.1 Setting the Covers
2.4.1.1 Overview
Fig.19: Cover switch
1. Cover switch
2.4.1.2 Adjusting the Cover Switch
Fig.20: Cover switch [03110691-xx]
► Loosen the screws(1) fastening the cover switch
to the bracket, so that the assembly can be easily
moved.
Fig.21: Cover switch
► Close the cover far enough for the actuator to be
just over the switch. Align them so that the metal
bracket is parallel to the opening in the switch.
The metal bracket may not scrape against the
cover switch.
► Tighten the cover switch screws in this position.

2 Basic Machine
2.5 Replacing the Machine Feet [03120976-xx]
Service Manual SIPLACE TX Series 06/2017 31
2.5 Replacing the Machine Feet [03120976-xx]
Parts, equipment and tools
●
Machine foot D 90mm [03120976-xx]
●
Operating manual for your machine
Removal / Installation
► Please read the relevant chapter of the user manual:
– "Setting the conveyor height and aligning the machine"

2 Basic Machine
2.5 Replacing the Machine Feet [03120976-xx]