7 Conveyor 7.3 Conveyor Drive 148 Service Manual SIPLACE TX Series 06/2017 Fig.201: Fastening screws ► Remove the three screws (1) fastening the con- veyor drive. ► Carefully unthread the motor from the toothed belt an…

100%1 / 316
7 Conveyor
7.3 Conveyor Drive
Service Manual SIPLACE TX Series 06/2017 147
Removal
Use the software or manually move the conveyor rail into a position which allows you best ac-
cess.
To move the conveyor rail manually, pull the toothed belt of the width adjustment unit.
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Move all gantries out of the transport area as far as possible at one side of the machine.
The fastening screws of the conveyor drives are on the outer side of the conveyor. You may
have to move out the COTi to get access to these screws. In this case follow the instructions
to move out the COTi.
Replacing the COTi Central Unit and Lifting Mechanics [}235]
Fig.199: Cable tie
Remove the cable tie(1) around the conveyor
drive.
Fig.200: Electrical connections
Unplug all electrical connections from the con-
veyor drive(1). You may want to mark their posi-
tions for easier exact replacement later on.
7 Conveyor
7.3 Conveyor Drive
148 Service Manual SIPLACE TX Series 06/2017
Fig.201: Fastening screws
Remove the three screws(1) fastening the con-
veyor drive.
Carefully unthread the motor from the toothed
belt and remove the motor from the machine.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
Make sure that the toothed belt is not folded or otherwise damaged.
Make sure that the toothed belt is accurately positioned in the guidance on the motor
shaft.
Carefully thread in the toothed belt. To do this, carefully lift the toothed belt a little (e.g.
with the shorter end of an Allen key).
Tighten the three screws fastening the conveyor drive hand-tight. Set the tension of
the toothed belt correctly in same time at 210+-20Hz.
Replace any cables ties where needed.
Replace, in particular, the cable tie on the motor. Make sure that the cables, cable ties
and, in particular, the cable tie heads are not damaged on edges or rubbed against
anything when you adjust the conveyor sides.
Also pay attention to the cable ties on the trailing cable and to the shield connection
on the conveyor drive.
Perform these checks along the whole width of the conveyor.
See also
2 Replacing the COTi Central Unit and Lifting Mechanics [}235]
2 Replacing the COTi Central Unit and Lifting Mechanics [}235]
7 Conveyor
7.3 Conveyor Drive
Service Manual SIPLACE TX Series 06/2017 149
7.3.2 Replacing the Toothed Belts (Conveyor Drives) [03121566-xx]
Parts, equipment and tools
Belt tension measuring device [00326015‑xx]
Select the required toothed belt:
1. Toothed belt Synchroflex 5+-0.1 AT3/201
[03121566‑xx]
210 +/- 20 Hz
2. Toothed belt Brecoflex 5+-0.1 AT3/1701
[03121584‑xx]
Width adjustment for conveyor in lane2 (longer,
outside)
21 +/- 2 Hz
3. Toothed belt Brecoflex 5+-0.1 AT3/1509
[03121586‑xx]
Width adjustment for conveyor in lane1 (shorter,
inside)
25 +/- 2 Hz
Overview
Fig.202: Conveyor drives and toothed belts
1. Conveyor drives in lane 1 (location 1)
2. Conveyor drives in lane 2 (location 2)
3. Six conveyor drives
4. Toothed belt for conveyor drives
5. Three screws fastening the conveyor drives