9 Nozzle Changers and Nozzle Stations
9.2 Replacing the Nozzle Changer
Service Manual SIPLACE TX Series 06/2017 227
9.2 Replacing the Nozzle Changer
Parts, Equipment and Tools
NC basic structure CPx/all assembly short [03103649-xx]
If required, NC adjusting plates [03021079-xx]
Depth measuring gauge (300mm) [03079617-xx]
Overview
Fig.306: Nozzle changer with four 4xxx magazines
1. Four nozzle magazines
2. Four fastening screws
3. Four levers for removal of nozzle magazines
4. Cover on the underside
The electronic and pneumatic components are
under the cover.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove all magazines.
Remove the four fastening screws.
Unplug the nozzles changer from all electrical and pneumatic connections.
Take care not to lose the support plates.
Carefully lift the nozzle changer out of the machine.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
Set the switch on the nozzle changer to 2-3 (valid for all SIPLACE TX machines).
Check the mechanical installation height of the nozzle changer (see 9.2.1 "Setting the
Nozzle Changer Height" [}228]).
9 Nozzle Changers and Nozzle Stations
9.2 Replacing the Nozzle Changer
228 Service Manual SIPLACE TX Series 06/2017
9.2.1 Setting the Nozzle Changer Height
Parts, Equipment and Tools
Measuring scale
NC shim plate (0.3mm) [03021079-xx]
Overview
Fig.307: Overview of Measurement Procedure
1. Measuring scale
2. Top edge of the X axis upper linear guide
3. Values to be set (277 +/- 0.2 mm)
4. Nozzle changer contact surface
 NOTICE!
Alternatively, you can measure from the top
edge of the lower guide rail of the gantry. In this
case the distance is 116.0+/‑0.2mm.
.
Setting
DANGER
Strong permanent magnet fields
Observe the safety instructions in section 1.1.2 "Safety Instructions for Working with Strong
Magnetic Fields" [}10].
Remove the nozzle changer (see 9.2 "Replacing the Nozzle Changer" [}227]).
During the following inside measurement make sure that the tip of the measuring scale does
not tough the magnetic strip as this might scratch it!
CAUTION
Strong magnetic forces
Place a suitable plastic plate between the magnet and measuring scale, if required.
Position the measuring scale(1) on the top edge of the X axis upper linear guide(2) and
measure the distance to the nozzle changer contact surface(4).
Hold the measuring scale vertically.
The setting value (3) is 277+/‑0.2mm.
You can adjust the height, where necessary, by removing or adding NC adjusting plates.
9 Nozzle Changers and Nozzle Stations
9.3 Replacing Nozzle Station [03090348-xx]
Service Manual SIPLACE TX Series 06/2017 229
CAUTION
Crash hazard!
Do not place too many adjusting plates underneath.
Calibrate the position of the nozzle changer.
9.3 Replacing Nozzle Station [03090348-xx]
Parts, equipment and tools
Nozzle station CPx complete / X4iS, XS [03090348-xx]
Measuring scale
Adjusting plates: support for nozzle reject device [03039514-xx]
Overview
Fig.308: Nozzle station
1. Nozzle station
2. Screws fastening the nozzle station
3. Hose
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the two screws(2) fastening the nozzle station(1).
Unplug the hose(3) for nozzle cleaning.
Remove the nozzle station.