6 Gantries 6.3 Trailing Cable and Printed Circuit Boards Service Manual SIPLACE TX Series 06/2017 107 Installation ► Installation is performed by following the above instructions in the reverse order. Also observe the fo…

100%1 / 316
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
106 Service Manual SIPLACE TX Series 06/2017
Fig.126: Holding-down device
Remove the two screws (2) fastening the holding-
down device (1) and then remove the holding.-
down device.
Open the cable clamp (3).
Unplug the connectors (4). You might like to mark
their positions to make clear assignment easier
later on.
Remove the two screws (5) fastening the trailing
cable clamp(6).
Fig.127: Trailing cable on the gantry
Remove the three screws(1). These screws are
not secured with Loctite.
Remove the two screws(2). These screws are
not secured with Loctite.
The trailing cable now lies loose in the machine.
Carefully remove the trailing cable from the machine.
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
Service Manual SIPLACE TX Series 06/2017 107
Installation
Installation is performed by following the above instructions in the reverse order. Also observe
the following instructions:
CAUTION
Installation instructions
If a vacuum pump is fitted, also observe the relevant assembly instructions
[00196845‑xx].
Always handle the new trailing cable with care.
You might need to enlist the help of a second person.
Make sure that the flat ribbon cable and the pneumatic hoses are not rubbed against
any parts or folded. Look out for sharp edges.
Prepare the trailing cable. Place the old and new trailing cables next to one another
and match the length of the new trailing cable hose to the old one.
You might find it helpful to mark the new hoses and connectors in the same way as
the old ones.
If hose ends were damaged during removal, cut these with hose cutters.
Clean the trailing cable contact surface on the machine base with a dry cloth.
Carefully insert the new trailing cable into the prescribed position. Make sure you do
not fold or twist the trailing cable.
Secure screws with Loctite 241 (see below).
Fit the board cover. Make sure that you do not cause a short circuit.
Fig.128: Covers
Secure the screws(2) of the upper cover with
Loctite 241.
 CAUTION!
Do not secure the screws(1) of the lower
cover with Loctite.
.
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
108 Service Manual SIPLACE TX Series 06/2017
Fig.129: Trailing cable on the gantry
 CAUTION!
Do not secure the screws(1) and(2) with
Loctite.
.
6.3.6.2 Replacing the Y Axis Trailing Cable
Parts, equipment and tools
Fig.130: Trailing cable
Trailing cable Y TX gantry 1 [03112680‑xx]
Trailing cable Y TX gantry 2 [03112675‑xx]
Hose unlocking tool [03047090-xx]
Pipe/hose cutters [00381443-xx]
If needed, assembly instructions "Vacuum pump option for SIPLACE TX-Series" [DE
+EN:00198147‑xx]
Loctite 241 [02101037‑xx]
Edding marker, white [00382740-xx]
You might find it advisable to enlist the help of a second person.
Removal
NOTICE
Vacuum pump
When a vacuum pump is fitted, also observe the assembly instructions "SIPLACE TX
Vacuum Pump" [00198147‑xx].
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].