Measuring Equipment and Tools SIPLACE Axis Tester (SAT) [03002801-01] Service Manual SIPLACE D1/D1i/D2/D2i 193 5 5 M e a s u r in g E q u ip m e n t a n d T o o ls Measuring Equipment and Tools 5.1 5 . 1 S I P L A C E A …

100%1 / 280
Service Work
Cutter 4.8.6 Replacing the Cutter Blades [03009259-xx]
192 Service Manual SIPLACE D1/D1i/D2/D2i
Final work
Reinsert the tape deflector unit (3) and screw in the 4
hexagon socket-head screws (4) by hand.
Push the spacers (with inserted shim) as far as pos-
sible in the direction of the moveable blade. The max-
imum permissible gap is 1.0 mm.
In this position, tighten the 4 screws (4) on the tape
deflector holder crosswise (tightening torque).
Remove the two shim rings.
Insert the new stationary blade (5) in the correct po-
sition and screw tight.
1
2
4
1
5
4
3
2
Use a feeler gauge to check the gap between the
tape deflector (1) and the moveable blade (2), along
the entire length and width of the blade.
⇨ The 0.05 mm feeler gauge should fit through the
gap.
⇨ The 0.25 mm feeler gauge should not fit through
the gap.
If the gap is not correct, check:
Whether the wrong holding-down device has been in-
stalled (with function status < 03)
The holding-down devices are those designed for
cutters with function status -04 (= with tape deflector)
Whether the blades, tape deflector etc. were cleaned
before installation
If the gap is correct:
Replace the protective sheet, deflector plate and cov-
er plate. Make sure that the edges are parallel.
CAUTION! Check how the cables are run!
Make sure that the cables and hoses are not pinched or
subjected to excess strain.
Remove the clamps form the cutter/ remove the cut-
ter from the assembly plate.
Fit the cutter.
1
2
Measuring Equipment and Tools
SIPLACE Axis Tester (SAT) [03002801-01]
Service Manual SIPLACE D1/D1i/D2/D2i 193
5
5 Measuring Equipment and Tools
Measuring Equipment and Tools
5.1
5.1 SIPLACE Axis Tester (SAT) [03002801-01]
SIPLACE Axis Tester (SAT) [03002801-01]
Axis tester - view from above
1. LCD display with 240 x 128 pixels, black-and-white display, with background illumination
The LCD display shows the menus and the recorded trigger, track and position signals. All relevant
parameters, such as
Time basis,
Time measurement values,
Signal levels and
Cursor positions with the corresponding time deviation values
are shown as alphanumerical data in the diagram of the measurement curves.
2. Dynamic function display of BNC socket arrangement on the LCD display
3. Dynamic function display of foil button arrangement on the LCD display
4. Five foil buttons for menu control
5. Green LED for displaying operation
NOTICE
A363, A364
The axis tester is designed for all machines with A363. This function is limited for machines
with A364.
Measuring Equipment and Tools
SIPLACE Axis Tester (SAT) [03002801-01]
194 Service Manual SIPLACE D1/D1i/D2/D2i
Axis tester - view from below
1. Connection for flat ribbon cable:
At the axis tester end:
– 37-pin sub-d connector
At the axis control end:
– 37-pin sub-d connector for the S-20/23/25/F4/F5 and HS-50 machines with the axis control
A361 or A362
25-pin sub-d connector for the S-15/F3, G machines and wafflepack changer with the axis con-
trol A360
An adapter is fitted to the flat ribbon cable to connect the 25-pin axis control. The operating volt-
ages of +5 V- ±5 % and ±15 V- ±5 % are fed via the 37 pin flat ribbon cable from the axis control
unit to the axis tester.
2. 9 pin Sub-D connector for CAN Bus cable e.g. for connection of CAN Bus controlled boards in the
machine – currently not used (transmission rate 128 kBaud to 1 MBaud, impedance 120 Ohm)
3. 9 pin Sub-D connector for the serial interface cable (V24) needed for software downloads, e.g. for
connection of an external PC (max. transmission rate up to 188 kBaud)
4. Four BNC sockets, connection impedance 50 Ohm. Socket assignment can be programmed. The
following signals can be assigned:
Track signal A or B TTL level, max. 5 V
Zero pulse TTL level tmin = 1 µsec
End position signal TTL level tmin > 10 msec
Trigger TTL level tmin > 10 msec
Count error TTL level, trigger signal from count error sensor of oscilloscope
Vtarget ±10 V, analog signal, Ri = 10 kOhm
Force ±10 V analog signal, Ri = 10 kOhm
VREG (resulting current) ±10 V analog signal, Ri = 10 kOhm
Position deviation ±10 V analog signal; signal is generated internally, in the axis tester.