Service Work 4.2.8 Replacing the X-Axis In cremental Encoder (Read Head) [030 47215S-xx] Gantries Service Manual SIPLACE D1/D1i/D2/D2i 77 Installation ► Clean the reading surface of the incremental encoder with a cloth a…

100%1 / 280
Service Work
Gantries 4.2.8 Replacing the X-Axis Incremental Encoder (Read Head) [03047215S-xx]
76 Service Manual SIPLACE D1/D1i/D2/D2i
Press-fit connections
Removal
Assembly Gantry Board Terminals
X axis incremental en-
coder
Gantry 1 (C&P head ) Gantry head distributor
[03039274-xx]
X15ac
X axis incremental en-
coder
Gantry 2 (P&P head ) Gantry head distributor
[03039274-xx]
X15bc
Unthread the connection cable as far as the incre-
mental encoder (3).
Loosen the screws (4) fastening the incremental en-
coder (3) of the X axis and carefully lift off the incre-
mental encoder.
Service Work
4.2.8 Replacing the X-Axis Incremental Encoder (Read Head) [03047215S-xx] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 77
Installation
Clean the reading surface of the incremental encoder
with a cloth and ethanol or with a Q-tip.
Loosely fasten the incremental encoder (3) with the
screws (4).
The incremental encoder must be aligned with a 0.4
mm gap to the scale. Use the corresponding thick-
ness gauge (plastic).
Casting marks on the incremental encoder (X-axis on X-
series machine shown as example)
You must set the exact height to the scale.
Align the incremental encoder, using the two casting
marks (arrows), which mark the read area.
Service Work
Gantries 4.2.9 Replacing the Y-Axis Incremental Encoder (Read Head) [03047216S-xx]
78 Service Manual SIPLACE D1/D1i/D2/D2i
Installation
4.2.9
4.2.9 Replacing the Y-Axis Incremental Encoder (Read Head) [03047216S-xx]
Replacing the Y-Axis Incremental Encoder (Read Head) [03047216S-xx]
Tighten the fastening screws (4).
Reconnect to the electricity supply.
CAUTION! Check how the cables are run!
Make sure that the axes can be moved without damaging
the cables.
Fasten them with cable ties.
Move the gantry into the end stopper and check that
the bumper does not come into contact with the ca-
ble.
Position of incremental encoder (Y-axis) and the gantry
interface (X-series machine shown as example)
Legend
1. Position of Y-axis incremental encoder (read head)
2. Installation point for gantry interface
Move the gantry to a suitable position (D1: left side of
machine, D2: center of machine), so that you have
access the incremental encoder easily.
Unplug the incremental encoder press-fit connection
from the gantry interface (2).
1