00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第62页

Service Work Gantries 4.2.2 Replacing the Tensioning Keys [00329478-xx] 62 Service Manual SIPLACE D1/D1i/D2/D2i Elastomeric spri ng (arrangement in D4 shown) Legend ► Loosen the M8x20 hexagon socket-head scr ew in the dr…

100%1 / 280
Service Work
4.1.10 Replacing the Protective Cover Switch [00335263-XX] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 61
4.1.10
4.1.10 Replacing the Protective Cover Switch [00335263-XX]
Replacing the Protective Cover Switch [00335263-XX]
Removal/Installation
4.2
4.2 Gantries
Gantries
4.2.1
4.2.1 Replacing the Elastomeric Spring [00301040-XX]
Replacing the Elastomeric Spring [00301040-XX]
Tools and equipment
Set of DIN 911 Allen keys
Parts
Elastomeric spring 25 x 10.5 x 50, [00301040-xx]
Removing the elastomeric spring
Switch the machine off and secure it to prevent unauthorized reactivation as described in section.
Tools and equipment required
Detailed circuit diagrams for SIPLACE D series [Ger-
man: 00194841-xx] [English: 00194842-xx]
Legend
1. Installation position of cover switch at the input/output
side (when cover is open)
2. Cover switch with connection cable, complete
Where necessary, dismantle the covers.
Label the appropriate connections at the sector dis-
tributor.
Unplug the connection cable.
Unthread the connection cable as far as the cover
switch (1). Where necessary, dismantle the covers.
Loosen the screws fastening the cover switch.
Fit the new cover switch.
Rethread the connection cable and plug in the elec-
trical connections.
Close the protective cover and check that the cover
switch engages properly and is actuated.
Correct the position of the cover switch at the slots.
Switch the machine on and check that the cover
switch activates the safety circuit, when the protective
cover is opened.
Fit the covers.
DANGER
POWERFUL MAGNETIC FIELD
Always follow the special safety instructions when working in the vicinity of powerful mag-
netic fields (see section).
Service Work
Gantries 4.2.2 Replacing the Tensioning Keys [00329478-xx]
62 Service Manual SIPLACE D1/D1i/D2/D2i
Elastomeric spring (arrangement in D4 shown)
Legend
Loosen the M8x20 hexagon socket-head screw in the drilling in the elastomeric spring.
Installing the elastomeric spring
Use the M8 x 20 hexagon socket-head screw to fix the elastomeric spring.
Settings
None.
4.2.2
4.2.2 Replacing the Tensioning Keys [00329478-xx]
Replacing the Tensioning Keys [00329478-xx]
Tools and equipment
Set of DIN 911 Allen keys
Belt tension measuring device TSM [00326015-xx]
"Measuring belt tensions" operating instructions
Parts
Tensioning keys [00329478-xx]
Tensioning keys [03044521-xx]
1 Elastomeric spring for X-axis 3 All gantries: elastomeric spring for Y-axis
2 Gantries 1 and 3: elastomeric spring for the
Y-axis
Gantries 2 and 4: bracket instead of elasto-
meric spring
Service Work
4.2.2 Replacing the Tensioning Keys [00329478-xx] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 63
Removing the tensioning keys
Replacing the tensioning keys (D4 shown as example)
Legend
Switch the machine off and secure it to prevent unauthorized reactivation as described in section.
Push the head mount in the direction of the deflection pulley (6).
To relax the toothed belt (5), proceed as follows:
⇨ Loosen the locknut (11) and
⇨ Turn the hexagon socket-head screw (3) counterclockwise.
Removing the tensioning key, item 1 (synchronizing disk, short)
Loosen the M4 x 5 hexagon socket-head screw (8).
1 Tensioning keys [00329478-xx] 7 Spacer bolt with Benzing U-clip
2 Tensioning keys [03044521-xx] 8 M4 x 5 hexagon socket-head screw
3 M4 x 35 hexagon socket-head screw for
tensioning the toothed belt
9 Synchronizing disk, short
4 Head mount 10 Synchronizing disk, long
5 Toothed belt for the X-axis 11 Locknut
6 Deflection pulley