00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第202页

Measuring Equipmen t and Tools Calibration Nozzle for Twin Head [03008862-xx] 5.1.1 Scope of Delivery 202 Service Manual SIPLACE D1/D1i/D2/D2i

100%1 / 280
Measuring Equipment and Tools
5.1.1 Scope of Delivery Calibration Nozzle for TwinHead [03008862-xx]
Service Manual SIPLACE D1/D1i/D2/D2i 201
5.13
5.13 Calibration Nozzle for TwinHead [03008862-xx]
Calibration Nozzle for TwinHead [03008862-xx]
Use:
The calibration nozzle is used to calibrate the D axis of
the TwinHead or P&P head.
NOTICE!
This nozzle is no longer needed from SW705.03.
Measuring Equipment and Tools
Calibration Nozzle for TwinHead [03008862-xx] 5.1.1 Scope of Delivery
202 Service Manual SIPLACE D1/D1i/D2/D2i
Settings
6.1.1 Checking the Firmware Function Electrical System
Service Manual SIPLACE D1/D1i/D2/D2i 203
6
6 Settings
Settings
6.1
6.1 Electrical System
Electrical System
6.1.1
6.1.1 Checking the Firmware Function
Checking the Firmware Function
6.1.2
6.1.2 Firmware Download Note
Firmware Download Note
From the following station software versions, the firmware download can be performed to all CAN bus
nodes, via the standard SITEST interface.
505.04 SP2
603.01 SP1
604.01 SP1
6.2
6.2 Gantries
Gantries
6.2.1
6.2.1 Travel Ranges and Speed Monitoring
Travel Ranges and Speed Monitoring
The travel range of the X and Y axes is determined automatically with the SITEST program.
This means that, during travel range calibration, the axis concerned moves as far as possible towards
the minimum or maximum position, until the set target value is no longer reached by the axis card. It is
then assumed that the hardware end stopper (bumper) has been reached. In a time window of approx.
10 ms, the greatest actual value achieved is taken to calculate the travel range.
To guarantee an appropriate safety distance before the hardware end stopper is touched, a certain dis-
tance is deducted from the set travel range. This enables the axis to brake in time, even when errors
occur.
Select a Target (BIOS/application 1/application 2)