00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第60页

Service Work Electrical System 4.1.8 Replacin g the CAN Inte rface Board [03032 346-xx] 60 Service Manual SIPLACE D1/D1i/D2/D2i 4.1.8 4 . 1 . 8 R e p la c in g t h e C A N I n t e r f a c e B o a r d [ 0 3 0 3 2 3 4 6 - …

100%1 / 280
Service Work
4.1.6 Computer Unit - Replacing Parts Electrical System
Service Manual SIPLACE D1/D1i/D2/D2i 59
4.1.6
4.1.6 Computer Unit - Replacing Parts
Computer Unit - Replacing Parts
4.1.7
4.1.7 CAN Bus Terminator Board for Changeover Table [03046863-xx]
CAN Bus Terminator Board for Changeover Table [03046863-xx]
Removal/Installation
Jumper setting for CAN terminator circuit
Legend
1. Station computer (Box PC) [03032341-xx]
2. Machine Controller (Micro Box PC) [03047697-xx]
3. Hotlink interface [03032343-xx]
4. Video multicoupler [03040316-xx]
5. USB hub 2.0 [03032344-xx]
6. Portable USB DVD/CD drive [03051205-xx]
CAUTION! If necessary, perform data backup
before replacing any parts.
Detach all connections to the relevant part and label
these for easier reconnection, later.
Loosen any fixtures and remove the part.
Fit the new part by following the above instructions in
reverse order and configure the part, where required.
Legend
1. CAN Bus terminator board - changeover table in main
distributor (transport direction to left)
2. CAN Bus terminator board - changeover table in sub-
distributor (transport direction to right)
Detach all connections to the board to be replaced.
Label these for easier reconnection, later.
Remove the board.
Fit the new board and reestablish all connections.
Set the jumper on the board according to the relevant
sector, as shown in the following table:
Jumper Subdistributor Main distributor
1ONOFF
2ONON
Service Work
Electrical System 4.1.8 Replacing the CAN Interface Board [03032346-xx]
60 Service Manual SIPLACE D1/D1i/D2/D2i
4.1.8
4.1.8 Replacing the CAN Interface Board [03032346-xx]
Replacing the CAN Interface Board [03032346-xx]
Removal/Installation
4.1.9
4.1.9 Replacing the Monitor 1/2 [03040876-xx]
Replacing the Monitor 1/2 [03040876-xx]
Removal/Installation
Legend
1. CAN interface board in main distributor
Switch off the machine.
Open the main distributor.
Unscrew the board and unplug all connections. Label
these for easier reconnection, later.
Remove the board.
Insert the new board and reestablish all connections.
Unplug the connections (24 V voltage supply, video,
USB).
Unscrew the old monitor (1) and fit the new monitor.
Calibrate the touchscreen function of the new moni-
tor.
Service Work
4.1.10 Replacing the Protective Cover Switch [00335263-XX] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 61
4.1.10
4.1.10 Replacing the Protective Cover Switch [00335263-XX]
Replacing the Protective Cover Switch [00335263-XX]
Removal/Installation
4.2
4.2 Gantries
Gantries
4.2.1
4.2.1 Replacing the Elastomeric Spring [00301040-XX]
Replacing the Elastomeric Spring [00301040-XX]
Tools and equipment
Set of DIN 911 Allen keys
Parts
Elastomeric spring 25 x 10.5 x 50, [00301040-xx]
Removing the elastomeric spring
Switch the machine off and secure it to prevent unauthorized reactivation as described in section.
Tools and equipment required
Detailed circuit diagrams for SIPLACE D series [Ger-
man: 00194841-xx] [English: 00194842-xx]
Legend
1. Installation position of cover switch at the input/output
side (when cover is open)
2. Cover switch with connection cable, complete
Where necessary, dismantle the covers.
Label the appropriate connections at the sector dis-
tributor.
Unplug the connection cable.
Unthread the connection cable as far as the cover
switch (1). Where necessary, dismantle the covers.
Loosen the screws fastening the cover switch.
Fit the new cover switch.
Rethread the connection cable and plug in the elec-
trical connections.
Close the protective cover and check that the cover
switch engages properly and is actuated.
Correct the position of the cover switch at the slots.
Switch the machine on and check that the cover
switch activates the safety circuit, when the protective
cover is opened.
Fit the covers.
DANGER
POWERFUL MAGNETIC FIELD
Always follow the special safety instructions when working in the vicinity of powerful mag-
netic fields (see section).