00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第60页
Service Work Electrical System 4.1.8 Replacin g the CAN Inte rface Board [03032 346-xx] 60 Service Manual SIPLACE D1/D1i/D2/D2i 4.1.8 4 . 1 . 8 R e p la c in g t h e C A N I n t e r f a c e B o a r d [ 0 3 0 3 2 3 4 6 - …

Service Work
4.1.6 Computer Unit - Replacing Parts Electrical System
Service Manual SIPLACE D1/D1i/D2/D2i 59
4.1.6
4.1.6 Computer Unit - Replacing Parts
Computer Unit - Replacing Parts
4.1.7
4.1.7 CAN Bus Terminator Board for Changeover Table [03046863-xx]
CAN Bus Terminator Board for Changeover Table [03046863-xx]
Removal/Installation
Jumper setting for CAN terminator circuit
Legend
1. Station computer (Box PC) [03032341-xx]
2. Machine Controller (Micro Box PC) [03047697-xx]
3. Hotlink interface [03032343-xx]
4. Video multicoupler [03040316-xx]
5. USB hub 2.0 [03032344-xx]
6. Portable USB DVD/CD drive [03051205-xx]
CAUTION! If necessary, perform data backup
before replacing any parts.
► Detach all connections to the relevant part and label
these for easier reconnection, later.
► Loosen any fixtures and remove the part.
► Fit the new part by following the above instructions in
reverse order and configure the part, where required.
Legend
1. CAN Bus terminator board - changeover table in main
distributor (transport direction to left)
2. CAN Bus terminator board - changeover table in sub-
distributor (transport direction to right)
► Detach all connections to the board to be replaced.
Label these for easier reconnection, later.
► Remove the board.
► Fit the new board and reestablish all connections.
► Set the jumper on the board according to the relevant
sector, as shown in the following table:
Jumper Subdistributor Main distributor
1ONOFF
2ONON

Service Work
Electrical System 4.1.8 Replacing the CAN Interface Board [03032346-xx]
60 Service Manual SIPLACE D1/D1i/D2/D2i
4.1.8
4.1.8 Replacing the CAN Interface Board [03032346-xx]
Replacing the CAN Interface Board [03032346-xx]
Removal/Installation
4.1.9
4.1.9 Replacing the Monitor 1/2 [03040876-xx]
Replacing the Monitor 1/2 [03040876-xx]
Removal/Installation
Legend
1. CAN interface board in main distributor
► Switch off the machine.
► Open the main distributor.
► Unscrew the board and unplug all connections. Label
these for easier reconnection, later.
► Remove the board.
► Insert the new board and reestablish all connections.
► Unplug the connections (24 V voltage supply, video,
USB).
► Unscrew the old monitor (1) and fit the new monitor.
► Calibrate the touchscreen function of the new moni-
tor.

Service Work
4.1.10 Replacing the Protective Cover Switch [00335263-XX] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 61
4.1.10
4.1.10 Replacing the Protective Cover Switch [00335263-XX]
Replacing the Protective Cover Switch [00335263-XX]
Removal/Installation
4.2
4.2 Gantries
Gantries
4.2.1
4.2.1 Replacing the Elastomeric Spring [00301040-XX]
Replacing the Elastomeric Spring [00301040-XX]
Tools and equipment
▪ Set of DIN 911 Allen keys
Parts
▪ Elastomeric spring 25 x 10.5 x 50, [00301040-xx]
Removing the elastomeric spring
► Switch the machine off and secure it to prevent unauthorized reactivation as described in section.
Tools and equipment required
▪ Detailed circuit diagrams for SIPLACE D series [Ger-
man: 00194841-xx] [English: 00194842-xx]
Legend
1. Installation position of cover switch at the input/output
side (when cover is open)
2. Cover switch with connection cable, complete
► Where necessary, dismantle the covers.
► Label the appropriate connections at the sector dis-
tributor.
► Unplug the connection cable.
► Unthread the connection cable as far as the cover
switch (1). Where necessary, dismantle the covers.
► Loosen the screws fastening the cover switch.
► Fit the new cover switch.
► Rethread the connection cable and plug in the elec-
trical connections.
► Close the protective cover and check that the cover
switch engages properly and is actuated.
► Correct the position of the cover switch at the slots.
► Switch the machine on and check that the cover
switch activates the safety circuit, when the protective
cover is opened.
► Fit the covers.
DANGER
POWERFUL MAGNETIC FIELD
► Always follow the special safety instructions when working in the vicinity of powerful mag-
netic fields (see section).