Measuring Equipmen t and Tools Adjustment Valve Plunger for DLM Heads 5.1.1 Scope of Delivery 200 Service Manual SIPLACE D1/D1i/D2/D2i 5.11 5 . 1 1 A d ju s t m e n t V a lv e P lu n g e r f o r D L M H e a d s Adjustmen…

Measuring Equipment and Tools
5.1.1 Scope of Delivery Z End Stopper Star Gauge for C&P6/12 03019865-xx
Service Manual SIPLACE D1/D1i/D2/D2i 199
5.9
5.9 Z End Stopper Star Gauge for C&P6/12 03019865-xx
Z End Stopper Star Gauge for C&P6/12 03019865-xx
5.10
5.10 Adjustment Aid for C&P DLM 00327005-xx
Adjustment Aid for C&P DLM 00327005-xx
Use:
The gauge is used to set the end stop position of the C&P
head Z axis.
Complete set [00327005-xx]
1. Gauge for star [00326164-xx]
2. Test probe 1.4 mm [00326160-xx]
3. Test probe 1.5 mm [00326161-xx]
4. Test probe 1.6 mm [00326162-xx]
5. Test probe 1.0 mm [00376656-xx]
6. Distance gauge [00325445-xx]
Measurement tools Application type
Gauge for star Setting the zero point correction for the star
Test probe 1.4 mm Setting the distance between the DP station incremental encoder and the glass
for the sleeve
Test probe 1.5 mm
Test probe 1.6 mm
Test probe 1.0 mm Setting the distance from the Z axis light barrier down to the sleeve shaft
Distance gauge Setting the distance of the valve plunger to the star

Measuring Equipment and Tools
Adjustment Valve Plunger for DLM Heads 5.1.1 Scope of Delivery
200 Service Manual SIPLACE D1/D1i/D2/D2i
5.11
5.11 Adjustment Valve Plunger for DLM Heads
Adjustment Valve Plunger for DLM Heads
See also
6.5.1 Calibrating the C&P Head and Cameras [ ➙ 232]
5.12
5.12 Calibration Tool [03010565-xx]
Calibration Tool [03010565-xx]
Adjustment valve plunger DLM head
Available from positioning unit version 3
Use the 0.2 mm setting gauge with DLM1.
1. Adjustment valve plunger for reject circuit C&P12
[03064290-xx] (DLM2, DLM3)
2. Adjustment valve plunger for placement circuit
C&P12 [03068816-xx] (DLM2, DLM3, DLM4)
3. Adjustment valve plunger for reject circuit C&P6
[03068854-xx] (DLM2, DLM3)
The C&P6 is not used in the DX series.
4. Adjustment valve plunger for placement circuit C&P6
[03065628-xx] (DLM2, DLM3)
The C&P6 is not used in the DX series.
The labeling on the plungers has the following meaning:
▪ 6 = DLM head with 6 segments
▪ 12 = DLM head with 12 segments
▪ P = placement circuit
▪ R = reject circuit
Use:
The calibration tool [03010565-xx] is used for calibration
of the DLM, CPP, P&P heads, TwinHead and PCB cam-
era.

Measuring Equipment and Tools
5.1.1 Scope of Delivery Calibration Nozzle for TwinHead [03008862-xx]
Service Manual SIPLACE D1/D1i/D2/D2i 201
5.13
5.13 Calibration Nozzle for TwinHead [03008862-xx]
Calibration Nozzle for TwinHead [03008862-xx]
Use:
The calibration nozzle is used to calibrate the D axis of
the TwinHead or P&P head.
NOTICE!
This nozzle is no longer needed from SW705.03.