00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第76页

Service Work Gantries 4.2.8 Replacing the X-Ax is Incremen tal Encoder (Read He ad) [03047215S-xx] 76 Service Manual SIPLACE D1/D1i/D2/D2i Press-fit connections Removal Assembly Gantry Board Terminals X axis incremental …

100%1 / 280
Service Work
4.2.8 Replacing the X-Axis Incremental Encoder (Read Head) [03047215S-xx] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 75
4.2.8
4.2.8 Replacing the X-Axis Incremental Encoder (Read Head) [03047215S-xx]
Replacing the X-Axis Incremental Encoder (Read Head) [03047215S-xx]
Overview
Unplug the connection cable at the gantry head dis-
tributor and unthread it as far as the PCB camera (1).
Open the cable ties, where necessary.
Loosen the four screws fastening the PCB camera
mount (2).
Install the new PCB camera on the mount (2). Tighten
the screws and secure with loctite 241.
Run the connection cable to the gantry head distribu-
tor and reconnect to the electrical system.
Legend
1. Installation point for gantry head distributor with Vi-
sion board
2. Incremental encoder position
3. Incremental encoder (read head)
4. M3x6 fastening screws (fixed with Loctite No. 241)
Move the relevant changeover table out of the ma-
chine.
Shut down the machine and switch it off.
Unplug the incremental encoder (3) from the gantry
head distributor (1).
Service Work
Gantries 4.2.8 Replacing the X-Axis Incremental Encoder (Read Head) [03047215S-xx]
76 Service Manual SIPLACE D1/D1i/D2/D2i
Press-fit connections
Removal
Assembly Gantry Board Terminals
X axis incremental en-
coder
Gantry 1 (C&P head ) Gantry head distributor
[03039274-xx]
X15ac
X axis incremental en-
coder
Gantry 2 (P&P head ) Gantry head distributor
[03039274-xx]
X15bc
Unthread the connection cable as far as the incre-
mental encoder (3).
Loosen the screws (4) fastening the incremental en-
coder (3) of the X axis and carefully lift off the incre-
mental encoder.
Service Work
4.2.8 Replacing the X-Axis Incremental Encoder (Read Head) [03047215S-xx] Gantries
Service Manual SIPLACE D1/D1i/D2/D2i 77
Installation
Clean the reading surface of the incremental encoder
with a cloth and ethanol or with a Q-tip.
Loosely fasten the incremental encoder (3) with the
screws (4).
The incremental encoder must be aligned with a 0.4
mm gap to the scale. Use the corresponding thick-
ness gauge (plastic).
Casting marks on the incremental encoder (X-axis on X-
series machine shown as example)
You must set the exact height to the scale.
Align the incremental encoder, using the two casting
marks (arrows), which mark the read area.