00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第23页

Overview 3.2.2 Computer Unit Electrical System Service Manual SIPLACE D1/D1i/D2/D2i 23 3.2.2 3 . 2 . 2 C o m p u t e r U n it Computer Unit Computer unit Legend Overview of Settings 1 Station computer [03032341-xx] (Box …

100%1 / 280
Overview
Electrical System 3.2.1 Axis Unit
22 Service Manual SIPLACE D1/D1i/D2/D2i
3.2.1
3.2.1 Axis Unit
Axis Unit
Overview of Settings
Axis unit (D2 as example)
Legend
1. X-axis brake board, gantry 1
2. X-axis servo card, gantry 1
3. Star axis servo card, gantry 1
4. Z-axis servo card, gantry 1
5. Y-axis brake board, gantry 1
6. Y-axis servo card, gantry 1
7. X-axis brake board, gantry 2 (for D2 only)
8. X-axis servo card, gantry 2 (for D2 only)
9. Star axis servo card, gantry 2 (for D2 only)
10. Z-axis servo card, gantry 2 (for D2 only)
11. Y-axis brake board, gantry 2 (for D2 only)
12. Y-axis servo card, gantry 2 (for D2 only)
13. DP axis servo card, gantry 1
14. DP axis servo card, gantry 2 (for D2 only)
15. 2 A364 axis cards (D2 has 3 A364 axis cards)
16. Ballast circuit
17. Power supply 5V/15A, 2x15V/5A
18. Power supply 15V/5A
Description Setting Values
Complete axis unit re-
placed
Set the DIP switch for the relevant
location
At placement area 1(OFF/OFF)
Axis card A 364 Install firmware for the relevant axis See "4.1.4 Replacing the A364 Axis
Card" [ 57].
Servo cards No settings required The servo card for the respective axis
is defined by the hardware.
Overview
3.2.2 Computer Unit Electrical System
Service Manual SIPLACE D1/D1i/D2/D2i 23
3.2.2
3.2.2 Computer Unit
Computer Unit
Computer unit
Legend
Overview of Settings
1 Station computer [03032341-xx] (Box PC) 4 Video multicoupler [03040316-xx]
2 Machine controller [03047697-xx]
(Micro Box PC)
5 USB hub 2.0 [03032344-xx]
3 Hotlink interface [03032343-xx] 6 Portables USB/DVD/CD drive
[03051205-xx]
Description Setting Comments
Station computer replaced No settings required Backup of machine data
Install software according to respective in-
stallation guide.
Video multiplexer replaced No settings required
Hotlink interface replaced No settings required Make sure that card engages correctly in
the slot.
USB hub 2.0 replaced No settings required Make sure that the USB hub is connected
to the bottom left USB port.
Machine controller replaced No settings required Software installation for machine control-
ler
Overview
Electrical System 3.2.3 Power Supply Unit
24 Service Manual SIPLACE D1/D1i/D2/D2i
3.2.3
3.2.3 Power Supply Unit
Power Supply Unit
3.2.3.1
3.2.3.1 Supply Voltages
Supply Voltages
The power supply unit provides the following supply voltages:
200 V for the servo amplifier of the X and Y axes in the axis unit
150 V / 4 V- for the servo amplifier of the star in the axis unit
40 V for the servo amplifier of the Z and DP axes in the axis unit
52 V for the DC/DC converter in the subdistributor
40 V for the changeover tables and the PCB handling system
8 V for the changeover tables
Power supply unit
The power supply unit is located in the left of the central
machine section. A lockable door prevents unauthorized
access to the unit.