00195376-05_SM_D1_D1i_D2_D2i_EN.pdf - 第86页
Service Work PCB conveyor system 4.2.16 Hotlink Filter Card [03010670-xx] 86 Service Manual SIPLACE D1/D1i/D2/D2i 2. Non-modular PCB con veyor syste m with fitting the movable rail for width adjustment Non-modular convey…

Service Work
4.2.16 Hotlink Filter Card [03010670-xx] PCB conveyor system
Service Manual SIPLACE D1/D1i/D2/D2i 85
Modular conveyor, fixed rail

Service Work
PCB conveyor system 4.2.16 Hotlink Filter Card [03010670-xx]
86 Service Manual SIPLACE D1/D1i/D2/D2i
2. Non-modular PCB conveyor system with fitting the movable rail for width adjustment
Non-modular conveyor, movable rail

Service Work
4.3.1 Replacing the Complete Drive Unit [00359284] PCB conveyor system
Service Manual SIPLACE D1/D1i/D2/D2i 87
Non-modular conveyor, fixed rail
4.3.1
4.3.1 Replacing the Complete Drive Unit [00359284]
Replacing the Complete Drive Unit [00359284]
Overview
Example of input conveyor
Legend
1. Cable connections
2. Heat-shrinkable sleeves
3. Fastening screws
4. Conveyor toothed belt
5. Motor mount
6. Slot
7. Toothed disks
8. Belt guide
9. Deflection pulleys
The DC geared motors, including the motor mounts of all
3 conveyor areas, are of like construction. Please bear in
mind the following differences during assembly and dis-
assembly:
▪ The motor mount is installed either horizontally or
vertically, according to the requirements of the instal-
lation site.