4M184002w_F8S.pdf - 第104页
4OM-1840 1-4-29 1604-001 4.7.4 Center Spline Oiling Cycle : Every 3 Months (Required Time : 4 minutes) Grease : DAPHNE GREASE MP No.1 Center Spline Fig. 4A4-37 Procedure Apply grease to the groove of the center spline wi…

4OM-1840
1-4-281604-001
4.7.3 Diusion Plate Cleaning
Cycle : Every Month (Required Time : 5 minutes)
Diffusion Plate
Fig. 4A4-36
Procedure
(1) Store all nozzles in the nozzle stocker (housing) through window navigations.
Reference
Refer to "5. Nozzle Change Window" in "Chapter 6 (Vol. 2)" for the
procedure of nozzle storage.
Notice
Sebum or oil should not adhere to the surface of the diusion plate.
4.7 Head Section

4OM-1840
1-4-291604-001
4.7.4 Center Spline Oiling
Cycle : Every 3 Months (Required Time : 4 minutes)
Grease : DAPHNE GREASE MP No.1
Center Spline
Fig. 4A4-37
Procedure
Apply grease to the groove of the center spline with a syringe.
Note
Use No. 19 (brown) nozzle.
No.19
Fig. 4A4-38
4.7 Head Section

4OM-1840
1-4-301604-001
4.7.5 Cam Follower Cleaning and Oiling
Cycle : Every 3 Months (Required Time : 5 minutes)
Grease : DAPHNE GREASE MP No.1
Cam Followers
Fig. 4A4-39
Procedure
(1) If foreign substances adhere to the cam followers, remove them with a pair
of tweezers.
(2) Apply grease (0.01 cc) to the upper side of the cam face with a syringe.
Note
(a) "0.01 cc" is almost equivalent to the size of "1005 Chip".
(b) Use No. 19 (brown) nozzle.
No.19
Fig. 4A4-40
4.7 Head Section