4M184002w_F8S.pdf - 第97页

4OM-1840 1-4-22 1604-001 4.6.2 Cutter Unit Inside Oiling Cycle : Every 3 Months (Required Time : 10 minutes) Cutter Unit Screw (4 Locations) Fig. 4A4-28 Procedure (1) Remove the front cover . (2) Remove the cutter unit g…

100%1 / 315
4OM-1840
1-4-211604-001
4.6.1 Cutter Unit (Four Locations) Oiling
Cycle : Every 3 Months (Required Time : 10 minutes)
Grease : MOLYNOC GREASE AP1
Cutter Box
Grease Nipple
Fig. 4A4-27
Procedure
(1) Remove the front cover.
(2) Supply about 5cc of new grease from the grease nipple using the grease gun.
4.6 Cutter Section
4OM-1840
1-4-221604-001
4.6.2 Cutter Unit Inside Oiling
Cycle : Every 3 Months (Required Time : 10 minutes)
Cutter Unit
Screw (4 Locations)
Fig. 4A4-28
Procedure
(1) Remove the front cover.
(2) Remove the cutter unit guide cover.
(3) Clean the debris and dust in the cutter unit using a vacuum cleaner.
Note
Use a vacuum cleaner with a narrow air opening in the nozzle.
Narrow Air Opening in Nozzle End
(Recommended)
Fig. 4A4-29
CAUTION
After making sure that the air supply has been stopped and the
cutter blades are closed, start maintenance.
During maintenance, do not touch the cutter blade.
4.6 Cutter Section
4OM-1840
1-4-231604-001
4.7 Head Section
Diffusion Plate
Every Month Cleaning
Required Time: 2 minutes
Linear Measure Sensors
(Light Emitter and Receiver)
Every Day Cleaning
Required Time: 5 minutes
Nozzle U/D Ball Screw (NL Axis)
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
Head U/D Ball Screw
(high-speed multi-purpose head)
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
Head U/D Linear Guide (high-speed multi-purpose head)
Every 3 Months Cleaning and Lubrication
(DAPHNE GREASE MP No. 1)
Required Time: 5 minutes
Fig. 4A4-30
4.7 Head Section