4M184002w_F8S.pdf - 第172页

Error ID Error Name, Description, Cause, and Remedy 400d08 Software Interlock Error L1 axis(Head1) Interlock Detected. Please conrm the nozzle has not fallen when you push the beam by the hand. Please conrm detection o…

100%1 / 315
Error ID Error Name, Description, Cause, and Remedy
400b01 Feeder preparation complete
A pick up miss comp or disengaged Latch was detected.
Open the safety cover and conrm that there is no interference with the head, and
then, release the ready feeder.
400c01 Nozzle stocker down time out
Nozzle stock unit lower bound detection 1 was not turned on in prescribed time.
Please conrm the lower bound detection 1 sensor of nozzle stock unit.
400c02 Nozzle stocker down time out
Nozzle stock unit lower bound detection 2 was not turned on in prescribed time.
Please conrm the lower bound detection 2 sensor of nozzle stock unit.
400c03 Nozzle stocker down time out
Nozzle stock unit lower bound detection 3 was not turned on in prescribed time.
Please conrm the lower bound detection 3 sensor of nozzle stock unit.
400c04 Nozzle stocker down time out
Nozzle stock unit lower bound detection 4 was not turned on in prescribed time.
Please conrm the lower bound detection 4 sensor of nozzle stock unit.
400d01 Software Interlock Error
Head1 NL axis's poor operation was detected, and the scram of the XY axis was
carried out.
Please perform a zeroing.
400d02 Software Interlock Error
Head2 NL axis's poor operation was detected, and the scram of the XY axis was
carried out.
Please perform a zeroing.
400d03 Software Interlock Error
NL axis(Head2) Interlock Detected.
Please conrm the nozzle has not fallen when you push the beam by the hand.
Please perform a zeroing.
400d04 Software Interlock Error
NL axis(Head1) Interlock Detected.
Please conrm the nozzle has not fallen when you push the beam by the hand.
Please perform a zeroing.
400d05 Software Interlock Error
L1 axis(Head2) Interlock Detected.
Please conrm the nozzle has not fallen when you push the beam by the hand.
Please conrm detection of Pass Line, excess pushing.
400d06 Software Interlock Error
L2 axis(Head2) Interlock Detected.
Please conrm the nozzle has not fallen when you push the beam by the hand.
Please conrm detection of Pass Line, excess pushing.
400d07 Software Interlock Error
L3 axis(Head2) Interlock Detected
Please conrm detection of Pass Line, excess pushing.
3.1 Safety Device
4OM-1840
3-3-101604-001
Error ID Error Name, Description, Cause, and Remedy
400d08 Software Interlock Error
L1 axis(Head1) Interlock Detected.
Please conrm the nozzle has not fallen when you push the beam by the hand.
Please conrm detection of Pass Line, excess pushing.
400d09 Software Interlock Error
L2 axis(Head1) Interlock Detected.
Please conrm the nozzle has not fallen when you push the beam by the hand.
Please conrm detection of Pass Line, excess pushing.
400d0a Software Interlock Error
L3 axis(Head1) Interlock Detected.
Please conrm the nozzle has not fallen when you push the beam by the hand.
Please conrm detection of Pass Line, excess pushing.
400f01 Safety Cover
Safety cover opened
Close the safety cover and lock it.
400f02 Safety Cover
Failed in locking Simplied Cover.
-----
400f03 Safety Cover
Failed in locking Auto Cover.
-----
401001 Cart
No Cart
There is a possibility that the Front/Rear of Cart is missing. Please put the cart in.
401101 Emergency Stop Switch
The [emergency stop] switch was pressed.
(Please conrm the nozzle has not fallen when you push the beam by the hand.)
Please switch on a power supply after canceling an emergency stop switch and
screen return to normal display.
401201 Safety Cover
The safety cover opened. [S131,S132]
Please shut a safety cover and push the [POWER ON] button.
401301 Shut-o Beam
The main circuit of the XY Beam was broken. [K33A,K33B]
-----
401401 Head1 Nozzle descending
Head1 nozzle descent was detected. [A-B3104]
Please perform a zeroing.
401501 Head2 Nozzle descending
Head2 nozzle descent was detected. [B-B3104]
Please perform a zeroing.
401601 Head1 Nozzle descending
Head1 descent was detected. [A-B3103]
Please perform a zeroing.
3.1 Safety Device
4OM-1840
3-3-111604-001
Error ID Error Name, Description, Cause, and Remedy
401701 Head2 Nozzle descending
Head2 descent was detected. [B-B3103]
Please perform a zeroing.
401801 Detecting pickup miss Cmpnt(Block1)
A pickup-failed component (Block1) was detected. [DA-B0514]
1. Open the cover.
2. Conrm suppressor, Disengaged Latch and remove the Pickup miss cmpnt.
3. Close the cover and then Lock it.
401901 Detecting pickup miss Cmpnt(Block2)
A pickup-failed component (Block2) was detected. [DB-B0515]
1. Open the cover.
2. Conrm suppressor, Disengaged Latch and remove the Pickup miss cmpnt.
3. Close the cover and then Lock it.
401A01 Feeder Opening Sensor(Block1)
The feeder opening sensor (Block1) was shaded. [B****]
Please remove the factor which is shading the feeder opening sensor (Block1),
and carry out zero return.
401B01 Feeder Opening Sensor(Block2)
The feeder opening sensor (Block2) was shaded. [B****]
Please remove the factor which is shading the feeder opening sensor (Block2),
and carry out zero return.
401C01 Detecting Feeder Disengaged Latch(Block1)
Disengaged Latch(Block1) was detected.
1. Open the cover.
2. Conrm suppressor, Disengaged Latch and remove the Pickup miss cmpnt.
3. Close the cover and then Lock it.
401D01 Detecting Feeder Disengaged Latch(Block2)
Disengaged Latch(Block2) was detected.
1. Open the cover.
2. Conrm suppressor, Disengaged Latch and remove the Pickup miss cmpnt.
3. Close the cover and then Lock it.
401E01 Cancelling the safety cover lock
The safety cover lock was released.
Close the safety cover and lock it.
401F01 Detecting interlock of Head1
Head1 interlock was detected.
Please perform a zeroing.
402001 Detecting interlock of Head2
Head2 interlock was detected.
Please perform a zeroing.
402101 Detecting air pressure down
Air pressure down was detected.
Check air pipe came o or bend, air compressor.
3.1 Safety Device
4OM-1840
3-3-121604-001