4M184002w_F8S.pdf - 第119页

4OM-1840 1-4-44 1604-001 4.9.1 Backup T able Upper Surface Cleaning Cycle : Every Week (Required Time : 2 minutes) Backup Table Upper Surface Fig. 4A4-56 Procedure Remove foreign substances and unrequired components and …

100%1 / 315
4OM-1840
1-4-431604-001
4.9 PCB Positioning Section
Upper Surface of Backup Table
Every Week Cleaning
Required Time: 2 minutes
Ball Screws (3 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 10 minutes
Fig. 4A4-55
Upper Surface of Backup Table
Every Week Cleaning
Required Time: 2 minutes
The nipple are located on the lower side
of the backup table.
Ball Screw Spline (Four places to nipple)
Every 6 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 10 minutes
Note
Ball Screws (3 locations)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 10 minutes
Fig. 4A4-55-1 Y510mm Single Transfer Unit
Note
Either Y510mm or Y250mm single transfer unit can be selected when the
system is delivered from the factory.
4.9 PCB Positioning Section
4OM-1840
1-4-441604-001
4.9.1 Backup Table Upper Surface Cleaning
Cycle : Every Week (Required Time : 2 minutes)
Backup Table Upper Surface
Fig. 4A4-56
Procedure
Remove foreign substances and unrequired components and suck dirt and dust
with a vacuum cleaner.
Note
Either Y510mm or Y250mm single transfer unit can be selected when the system is
delivered from the factory.
4.9 PCB Positioning Section
4OM-1840
1-4-451604-001
4.9.2 Ball Screw Cleaning and Oiling
Cycle : Every 3 Months (Required Time : 10 minutes)
Grease : DAPHNE GREASE MP No.1
Ball Screw
Fig. 4A4-57
Procedure
(1) Wipe old grease out using a rag.
(2) Apply new grease on the screw shaft using a syringe.
Note
Perform the cleaning operation using the same procedure also in the system where the
Y510mm Single Transfer Unit (Factory option) has been mounted.
4.9 PCB Positioning Section