4M184002w_F8S.pdf - 第183页
Error ID Error Name, Description, Cause, and Remedy 420105 Backup(L) Error . T ime Over of the upward movement of stopper (L) 1. Check out the P .C.B. between stopper and conveyor 2. Error in Up/Down detection sensor . C…

3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
420001 Error in Transfer section
Transfer has errors.
-----
420002 Error in Transfer section
Transfer operation was not completed within a specied time.
-----
420003 Error in Transfer section
Positioning has errors.
-----
420004 Error in Transfer section
Input conveyor has errors.
-----
420005 Error in Transfer section
Positioning conveyor has errors.
-----
420006 Error in Transfer section
Output conveyor has errors.
-----
420007 Error in Transfer section
Interlock has been detected.
-----
420008 Error in Transfer section
Transfer was stopped.
-----
420101 Backup(L) Error.
The movement of Backup (L) Axis was not completed within predetermined time.
Backup axis is unable to do upward movement and downward movement.
The problem is for Motor, Driver, Sensor Error or wiring Error.
Please check the motor, sensor on Machine check screen.
420102 Backup(L) Error.
Driver Alarm on Backup (L) Axis
Check out reset Method of detailed Sub-system error counts of Alarm.
420103 Backup(L) Error.
Error in calculating data of Backup (L) Axis
Please check the following data
1. Machine Oset/Backup Pin(Up & Down)
2. Pattern program/P.C.B. information/P.C.B. size/thickness
3. Control/Common/PRE-PLACED CMPNT THKNS/Bottom of P.C.B.
420104 Backup(L) Error.
Time-over of zeroing of Backup (L) Axis
Check out the dirt, error, disconnection of sensor. If there is no problem with
sensor, the problem could be with motor wire/single error.
3.3 Conveyor
4OM-1840
3-3-211604-001

Error ID Error Name, Description, Cause, and Remedy
420105 Backup(L) Error.
Time Over of the upward movement of stopper (L)
1. Check out the P.C.B. between stopper and conveyor
2. Error in Up/Down detection sensor. Check out the sensor input
3. Disconnection, Error of Movement output. Please check Stopper by manual
movement if sensor input is proper.
4. Please set speed again by adjusting speed control when stopper is slow.
420106 Backup(L) Error.
Time-over of downward Stopper(L)
1. Up/Down Detect Sensor is out of order. Please check Sensor input
2. Disconnection/Error of output. Please check Stopper by manual movement if
sensor input is proper.
3. Please set speed again by adjusting speed control when stopper is slow.
420107 Backup(L) Error.
Communication Error of the command of P.C.B. positioning (Backup)
Error in Motor Driver, Communications trouble(AE-LINK), Error in Communication
P.C.B.(API). Check out the wiring of Communication line, power supply line.
420108 Backup(L) Error.
Backup Pin/Jig under the conveyor belt is detected.
Check out the interference in Belt on Backup Base does not exist.
420110 Backup (L) Error
Not ready for System setup of Backup (L) axis
Driver has not completed the parameter setup yet. It is a situation in which a
correct setup has not been received by Communication Error.
Check the Communication Mode, wiring, Power supply of Driver.
420111 Backup(L) Error
Error in zeroing in Backup(L) axis
LS, discontinuous zeroing movement, was detected. Check out the dirt, error of
sensor and error in Motor body etc.
420112 Backup(L) Error
Out-of-Control in Backup(L) axis is detected
Motor Out-of-Control which is over the width of Out-of-Control detecting occurred.
Please execute all zeroing again, and the restart production. Please set motor
speed slow if it happens frequently. Also, in a case of structure motor Error.
420113 Backup(L) Error
Error in motor power voltage of Backup(L) axis
Motor power voltage dropped. Check out the Power supply line(48V Line)
420114 Backup(L) Error
STP input of Backup(L) Axis is detected
STP input is detected. The function to stop motor by Hard signal.
420115 Backup(L) Error
Over-current of Backup(L)
Error in Motor output line. Check out the motor wiring.
3.3 Conveyor
4OM-1840
3-3-221604-001

Error ID Error Name, Description, Cause, and Remedy
420116 Backup(L) Error
Limit Sensor(+) of Backup(L) axis is detected
+LS signal was detected for moving for (+).
Please check the dirt of +LS sensor, disconnection.
420117 Backup(L) Error
Limit Sensor(-) of Backup(L) axis is detected
-LS signal was detected for moving for (-).
Please check the dirt of -LS sensor, disconnection.
420118 Backup(L) Error
Disconnecting Motor of Backup(L) axis is detected.
Disconnection to motor was detected.(Only stop mode)
Check the motor wiring.
420119 Backup(L) Error
Error in the Control Power Voltage of Backup(L) axis
Control power for driver dropped. Check out the Power supply line.(24V Line)
42011a Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011b Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011c Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011d Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011e Backup(L) Error
Reserved Code
Reserved Function of driver. Please make inquiries when error is detected.
42011f Backup(L) Error
System Error of Backup(L) axis
System Error of internal driver. Driver error is supposed if this problem happens
frequently.
420120 Backup(L) Error
Communication Error of the Backup(L) axis
1. Conrm connection to communication cable.
2. Conrm Power supply(24V).
3. Conrm the communication setting of PCI board.
4. Conrm the address of driver and communication rate setting.
420131 Backup(L) Error
Failed to adsorb PCB.
Please check the status of PCB, and perform positioning again.
3.3 Conveyor
4OM-1840
3-3-231604-001