4M184002w_F8S.pdf - 第276页
3.13 ACV Error ID Error Name, Description, Cause, and Remedy 740305 ACV:Feeder Location Error Feeder location error is found on tray (Block1). Conrm the position of components, and then do registrating operation. 740306…

Error ID Error Name, Description, Cause, and Remedy
700154 Barcode Detection
PCB nishing position Setup in Pattern Program diers before and after Program
Change.
-----
T4C18
3.12 Barcode Detection
4OM-1840
3-3-1141604-001

3.13 ACV
Error ID Error Name, Description, Cause, and Remedy
740305 ACV:Feeder Location Error
Feeder location error is found on tray (Block1).
Conrm the position of components, and then do registrating operation.
740306 ACV:Feeder Location Error
Feeder location error is found on tray (Block2).
Conrm the position of components, and then do registrating operation.
740501 ACV Time-out
Device(Block1) Time-out in receiving the result of ACV Check Error. Component
ID on the feeder is not same as one specied by current program.
-----
740502 ACV Time-out
Device(Block2) Time-out in receiving the result of ACV Check Error. Component
ID on the feeder is not same as one specied by current program.
-----
740605 ACV feeder check
Tray(Block1) parts empty.
Supply parts and register one.
-----
740606 ACV feeder check
Tray(Block2) parts empty.
Supply parts and register one.
-----
740701 ACV server timeout
ACV server process didn't respond in proper time.
-----
740702 ACV server timeout
-----
-----
740703 ACV server timeout
Error in an internal data ACV communication program. Please turn o a breaker.
-----
740704 ACV server timeout
Errors in the format of retrieval result of the ACV database.
-----
740705 ACV server timeout
Failed in the access to the ACV database.
-----
740706 ACV server timeout
The waiting time of the ACV database backup processing was exceeded.
-----
740707 ACV server timeout
There was no communication response from the ACV database.
-----
3.13 ACV
4OM-1840
3-3-1151604-001

Error ID Error Name, Description, Cause, and Remedy
740708 ACV server timeout
There was no communication response from the CPU1.
-----
740801 ACV check
The S/N of the machine didn't log in ACV server
-----
740802 ACV check
The S/N of the operator didn't log in ACV server
-----
740a01 ACV check
Starting of ACV tray tag reading went wrong.
-----
740f01 ACV check
Splicing registration failed.
-----
740f02 ACV check
Splicing registration failed for the unused feeder.
-----
740f03 ACV check
Abnormality was found in the connection with the ACV server. Please conrm the
ACV server. Please execute the server connection again on "MAINTENANCE"-
"UNIT ADJ"-"ACV ADJ"-screen after it conrms it.
-----
T4C19
3.13 ACV
4OM-1840
3-3-1161604-001