4OM-1840 1-4-37 1604-001 4.8.1 X-axis Linear Guide Check Cycle : Every Day (Required Time : 1 minute) X-Axis Linear Guides Fig. 4A4-48 Procedure Check it visually that no alien substance has been dropped. If any alien su…

4OM-1840
1-4-361604-001
(
Y-Axis Cable Fixing Places
Every 6 Months Inspection
Required Time: 1 minute
Y-Axis Cable Side Faces
Every 6 Months Cleaning and Lubrication
(BARRIERTA IEL/V)
Required Time: 3 minutes
Fig. 4A4-46
6
Y-Axis Linear Scale
Every 6 Months Cleaning
Required Time: 5 minutes
Fig. 4A4-47
4.8 X/Y Beam Section

4OM-1840
1-4-371604-001
4.8.1 X-axis Linear Guide Check
Cycle : Every Day (Required Time : 1 minute)
X-Axis Linear Guides
Fig. 4A4-48
Procedure
Check it visually that no alien substance has been dropped. If any alien substance
has been dropped, remove it.
4.8 X/Y Beam Section

4OM-1840
1-4-381604-001
4.8.2 X-axis Linear Guide Cleaning and Oiling
Cycle : Every 3 Months (Required Time : 5 minutes)
Grease : DAPHNE GREASE MP No.1
X-Axis Linear GuidesSlider
Fig. 4A4-49
Procedure
(1) Wipe old grease out using a rag.
(2) Apply new grease from the grease nipple using the hand grease gun.
Note
Grease should be applied every 3 months after the initial month.
Notice
Take ample care not to leave any waste threads after cleaning.
4.8 X/Y Beam Section