00191025-01.pdf - 第100页
5 Placement S IPLACE 80S/F/G User’s Manual 5.5 PCB Handling Ed ition 12/96 from Software Version SR.009.xx 5 - 24

SIPLACE 80S/F/G User’s Manual 5 Placement
Edition 12/96 from Software Version SR.009.xx 5.5 PCB Handling
5 - 23
fiducial can be made unrecognizable (defective printed circuit board or individual circuit). If the machine does
not recognize the ink spot, assembly of that printed circuit board or individual circuit does not take place. Ink
spots are especially suited to printed circuit boards which accommodate numerous identical individual circuits.
Ink spot recognition can be activated or deactivated within the "Machine options" menu after the
line engi-
neer password
has been entered.
If ink spot recognition is disabled, all printed circuit boards are assembled.
5.5.5 Width Adjustment
The width of the printed circuit board conveyor is normally set to the width of the printed circuit board for plac-
ing by a command from the line computer.
Manual adjustment of the conveyor width is possible within the single functions once the
line engineer pass-
word
has been entered. The procedure for this is described in more detail in Section 6.4.8 (Width Adjust-
ment).

5 Placement SIPLACE 80S/F/G User’s Manual
5.5 PCB Handling Edition 12/96 from Software Version SR.009.xx
5 - 24

SIPLACE 80S/F/G User’s Manual 5 Placement
Edition 12/96 from Software Version SR.009.xx 5.6 Error Menus
5 - 25
5.6 Error Menus
5.6.1 General
The error menus appear automatically on the screen after a fatal error. A fatal error means that the machine
cannot continue with placement without the intervention of the operator. When the error menus appears, you
are requested to press the start key in order to move the portal into the waiting position.
The menus "Track error 1" and "Track error 2" refer to the components table affected in each case. Since both
menus are identical, only the menu "Track error 1" will be described in this manual.
The menus "Machine error 1" and "Machine error 2" refer to the portal affected in each case. Since both
menus are also identical, here too only the menu "Machine error 1" will be described.
NOTE
As a standard procedure, only those functions are shown in the error menus which the operator can perform.
Only when the line engineer password has been entered is the full range of functions of the error menus
available.
All error menus can only be quit via the functions "Continue placement" or "Abort placement".
Following this error message you must select "Abort placement" once again if an operating error is to be
prevented.
WARNING
∆
!
∆
!
The functions, which are only accessible after the line engineer password has been entered, may only be
implemented by appropriately qualified and trained personnel, since improper handling of them may result in
injuries and/or damage to the machine.
NOTE
In the menus Track error, Machine error and Nozzle change the protective cover is unlocked and the x and y
axes isolated. In these menus, the axes can only be moved when the protective cover has been closed.
If head functions are selected, the key-operated switch will have to be turned with the cover open in order to
allow head functions to be used (for example, cycle star).
If the key-operated switch is activated when the protective cover is closed, the axes will be able to travel only
at the lower speed.