00191025-01.pdf - 第683页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 96 845 DP: Head in local files wrong or incomplete CAUSE ● Incorrec t head ente red in mach ine da…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 95
838 DP: Missing file name
CAUSE
●
File could not be found
REMEDY
●
Check data
839 DP: Cannot open file
CAUSE
●
An error occurred while the file was being read
REMEDY
●
Hard disk and file should be checked
840 DP: Cannot write file
CAUSE
●
While the file was being written an error occurred
REMEDY
●
Hard disk, file and file attribute (Read/Write) should be checked
841 DP: Cannot log on drive
CAUSE
●
Hardware error
REMEDY
●
Hardware and hard disk should be checked
842 DP: Cannot log off drive
CAUSE
●
Hardware error
REMEDY
●
Hardware and hard disk should be checked
843 DP: Cannot open fiducial file
CAUSE
●
Error while reading the fiducial file
REMEDY
●
Hard disk and file should be checked
844 DP: Cannot open fiducial list file
CAUSE
●
Error while reading the fiducial list file
REMEDY
●
Hard disk and file should be checked

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 96
845 DP: Head in local files wrong or incomplete
CAUSE
●
Incorrect head entered in machine data
REMEDY
●
Check machine data
846 DP: Loading of pack. form or fid. data not successful
CAUSE
●
Error while reading and loading the package form or fiducial data.
REMEDY
●
Data of package form and fiducial file should be checked
847 DP: Error in list for passpoint sets and fiducials
CAUSE
●
Error in real.ma and fiducial file
REMEDY
●
Data in real and fiducial files should be checked
848 Cannot save current MA data
CAUSE
●
Changing and rewriting aktuell.ma is not possible
REMEDY
●
Hard disk should be checked
849 VKL file cannot be stored
CAUSE
●
Not possible to rewrite the *.VKL file
REMEDY
●
Hard disk should be checked
850 Process data cannot be stored
CAUSE
●
Not possible to rewrite the glueing head process switches (C:\TMP\VL_PDAT.K1/2/3)
REMEDY
●
Hard disk should be checked
851 Process data cannot be read
CAUSE
●
1. At first time still no process data found
2. Error occurred during read
REMEDY
●
To 1. Not an error
To 2. File and hard disk should be checked

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 97
852 DP: Cannot save current MA data
CAUSE
●
Not possible to change or rewrite the aktuell.ma file
REMEDY
●
Hard disk should be checked
853 MA data: Invalid fiducial number for system fiducial
CAUSE
●
System fiducials must lie within the range 250 to 255
REMEDY
●
Correct the fiducial data in the MA data or set-up.
854 MA data: Error in sensor system types
CAUSE
●
Different sensor system types, or invalid for machine, in real.ma and ideal.ma
quoted (line computer telegram).
REMEDY
●
Make data consistent.
855 MA data: Missing height offset
CAUSE
●
Height offset not entered in real.ma.
REMEDY
●
Measure height offset and enter in real.ma.
856 MA data: Too many zero point fiducials
CAUSE
●
More than one zero point fiducial has been entered in ideal.ma.
REMEDY
●
Enter one fiducial only.
857 MA data: Mapping plate irregular
CAUSE
●
Irregular mapping plate is not supported.
REMEDY
●
Raster.px file should be checked; if necessary, remeasure
858 MA data: Error in nozzle type/vacuum correction values
CAUSE
●
For nozzle type in aktuell.ma no vacuum correction values can be found.
REMEDY
●
Enter valid nozzle type in aktuell.ma.