00191025-01.pdf - 第389页
9 Maintenance SIPLACE 80S /F/G User’s Manual 9.3 Machine Base Ed ition 07/97 from Software Vers ion SR.010.xx 9 - 30 Hose connector with hose clamp ● Check the pressure di splayed on lefthand m anometer (see Fig. 9.3 .5)…

SIPLACE 80S/F/G User’s Manual 9 Maintenance
Edition 07/97 from Software Version SR.010.xx 9.3 Machine Base
9 - 29
Fig. 9.3.5 Maintenance of the compressed air unit SIPLACE 80S and 80F
Key to
Fig. 9.3.5
1 Infeed of the compressed air supply
2 Drain plug for condensate
3 Filter cup, water trap
4 Manometer for operating pressure, 5.0 - 5.3 bar permissible range, permanently set
5 Stop valve for compressed air supply, placement head 1, in CLOSED position
6 Compressed air supply for vacuum generation, placement head 1
7 Compressed air supply for vacuum generation, placement head 2
8 Stop valve for compressed air supply, placement head 2, in CLOSED position
9 Compressed air regulator for the stopper
10 Connection for the components table pneumatics system
11 Manometer for compressed air supply to the stopper, 2.3 bar
12 Stop valve of the compressed air supply, in CLOSED position
13 ½" hose connector with hose clamp

9 Maintenance SIPLACE 80S/F/G User’s Manual
9.3 Machine Base Edition 07/97 from Software Version SR.010.xx
9 - 30
Hose connector with hose clamp
●
Check the pressure displayed on lefthand manometer (see Fig. 9.3.5): during operation the manometer
should display a pressure of 5.1 bar.
If this is not the case, this may be due to the following reasons:
–
The pressure in the supply network is too low. It must be 6 bar
–
The filter in the compressed air unit is contaminated
–
There is a leak in the compressed air supply or
–
The drain plug has not been tightened up or is leaky.
NOTE
For the compressed air supply use a ½" hose without reducer. The operating pressure of 5.6 bar is preset in
the compressed air unit and cannot be changed.
If it is not possible to achieve the operating pressure of 5.0 bar despite none of the above-mentioned reasons
applying, this means the compressed air unit is defective. You should inform Siemens’ SMD service depart-
ment.
9.3.5.2 2.3 bar Pressure for Stopper
●
Check the pressure displayed on the right-hand, upper manometer (see Fig. 9.3.5, Page 9 - 29): a pres-
sure of 2.3 bar must be displayed.
If this is not the case, remove the cover plate (see Fig. 9.1.1, Page 9 - 3) from the machine base (hexagon
socket spanner, size 3) and correct the setting at the adjustment knob up and to the right.
9.3.5.3 Draining the Condensate
NOTE
This work should only be carried out when there are no components at the star. The condensate will be blown
out under pressure.
●
Remove the cover plate from over the compressed air unit (hexagon socket spanner, size 3).
●
Hold a catch pan under the compressed air unit and unscrew and remove the drain plug (see Fig. 9.3.5,
Page 9 - 29). Finally screw the drain plug back in, making sure it is firmly seated.

SIPLACE 80S/F/G User’s Manual 9 Maintenance
Edition 07/97 from Software Version SR.010.xx 9.3 Machine Base
9 - 31
9.3.5.4 Replacing the Filter Cartridge, Cleaning the Filter Bowl
NOTE
This work should only be carried out when there are no components in the star as the machine needs to be
switched off for this work.
DANGER
∆
!
∆
!
∆
!
Switch the automatic placement system off at the main switch and disconnect from the power supply.
●
Remove the cover over the compressed air unit from the machine base
(see Fig. 9.1.1, Page 9 - 3). To do so, unscrew and remove the two special hexagon socket screws using
a size 3 hexagon socket spanner.
●
In addition turn off the compressed air supply at the stop valve of the compressed air unit (see Fig. 9.3.5,
Page 9 - 29).
●
Open the drain plug for draining the condensate to reduce the pressure in the compressed air hoses (see
Fig. 9.3.5, Page 9 - 29).
●
Remove the filter bowl by rotating it a quarter-turn and pulling it downwards (bayonet closure).
●
Clean the filter bowl if necessary. Only use soapy water for this.
●
Empty the condensate container.
●
Unscrew and remove the support spring and remove the sealing ring.
●
Pull the filter cartridge downwards and out.
●
Slide in the new filter cartridge.
●
Place the seal on the threaded rod and then screw on the support spring. The black plastic disk must be
placed in the filter bowl.
●
Screw the filter bowl back on.
●
Open the stop valve of the compressed air supply (see Fig. 9.3.5, Page 9 - 29).
●
Switch the machine back on at the main switch.
●
Check the pressure at both manometers:
–
operating pressure of the lefthand manometer: 5.6 bar
–
operating pressure for the stopper at the right-hand manometer: stopper: 2.3 bar
NOTE
If, despite changing the filter cartridges, the manometers still do not show 5.0 bar and 2.3 bar this will be
due to other reasons, as described in Section 9.3.5.1 from Page 9 - 28.
●
Fit the cover plate back on the machine base using the size 3 hexagon socket spanner.