SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 43 371 Calibration value is out of range (Er ror code 49H) CAUSE ● Error d uring the c ourse of ca …

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 42
364 Calibration value is out of range (Error code 42H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
365 Calibration value is out of range (Error code 43H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
366 Calibration value is out of range (Error code 44H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
367 Calibration value is out of range (Error code 45H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
368 Calibration value is out of range (Error code 46H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
369 Calibration value is out of range (Error code 47H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
370 Calibration value is out of range (Error code 48H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 43
371 Calibration value is out of range (Error code 49H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
372 Calibration value is out of range (Error code 4AH)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
373 Calibration value is out of range (Error code 4BH)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
374 Calibration value is out of range (Error code 4CH)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
375 Calibration value is out of range (Error code 4DH)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
376 Calibration value is out of range (Error code 4EH)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
377 Calibration value is out of range (Error code 4FH)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 44
378 Calibration value is out of range (Error code 50H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
379 Calibration value is out of range (Error code 51H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
380 Calibration value is out of range (Error code 52H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
381 Calibration value is out of range (Error code 53H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
382 Calibration value is out of range (Error code 54H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
383 Calibration value is out of range (Error code 55H)
CAUSE
●
Error during the course of calibration in the tester.
REMEDY
●
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
384 BERO SZ1 not released
CAUSE
●
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
●
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.