547 WPC: One tray of saved set-up missing
CAUSE
●
No tray present when changing levels; the "Tray in magazine" Bero is defective.
REMEDY
●
Fit new "Tray in magazine" Bero.
548 WPC: When returning tray, level occupied
CAUSE
●
Tray placed in travel range of the feed axis (when feed axis moved out);
the "Tray in magazine" Bero is defective.
REMEDY
●
Remove tray; fit new "Tray in magazine" Bero.
549 WPC: Tray has been taken out.
CAUSE
●
Ready tray was removed; the "Tray ready" Bero is defective.
REMEDY
●
Re-insert tray; fit new "Tray ready" Bero.
550 WPC: Take-over position already occupied
CAUSE
●
A tray already occupied the take-over position; the "Tray ready" Bero is defective.
REMEDY
●
Remove tray; fit new "Tray ready" Bero.
551 WPC: Tray in incorrect position or protection not closed properly.
CAUSE
●
Guard not correctly closed; tray positioned incorrectly; the "Lock against rotation " Bero is defective.
REMEDY
●
Close guard correctly; insert tray correctly; fit new "Lock against rotation" Bero.
552 WPC: Feed axis has touched protection.
CAUSE
●
The "Lock against rotation" Bero is defective; guard was opened during change procedure; tray
inserted incorrectly and driven against the guard.
REMEDY
●
Close guard; fit new "Lock against rotation" Bero; insert tray correctly.
553 Coplan.: Software error during system call RIO
CAUSE
●
Communication with the coplanarity module has been interrupted
REMEDY
●
Check the V-24 interface cable; check the jumper setting of the coplanarity module.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 70
554 Communication between SR and MC interrupted
CAUSE
●
Hardware fault in a module (M18, M34) or a wiring fault.
REMEDY
●
Replace modules; check the wiring at the back of the control unit.
555 Option nozzle changer IC head not set
CAUSE
●
The nozzle-changer was called without this option being set in the line computer.
REMEDY
●
Configure the nozzle-changer in the line computer.
556 Nozzle type not available
CAUSE
●
During nozzle changing or pick-up a nozzle type was demanded which lies outside the valid range.
REMEDY
●
Check the cluster and set-up.
557 Nozzle type not in set-up nozzle changer IC head
CAUSE
●
The nozzle type required was not included in the nozzle-changer set-up
REMEDY
●
Modify nozzle-changer set-up.
558 Error during MVS initialization via HS3L
CAUSE
●
Wiring of HS3L interface faulty; MVS card not inserted correctly in control unit.
REMEDY
●
Check HS3L wiring; check seating of the MVS card.
559 Data error in MC: Indices for optical centering not O.K.
CAUSE
●
The job data are inconsistent.
REMEDY
●
Check the camera records in the REAL.MA file; check the job data (GF data) in the line computer.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 71
560 Error during operation nozzle head control SP head
CAUSE
●
Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
●
Notify AUT 5 V Service Department
561 Modify nozzle changer SP head
CAUSE
●
The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
●
Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
●
Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line computer)
erroneous; incorrect sensor system type input at line computer
REMEDY
●
Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
●
Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
●
Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
564 Error during deletion of fiducials in MVS
CAUSE
●
Cannot occur
REMEDY
●