SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 31 290 Coplan.: Para meter number un known CAUSE ● Should not occu r. REMEDY ● 291 Coplan.: Attempt…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 30
283 VS: Unused free error number
CAUSE
Should not occur.
REMEDY
284 VS: A request is now being processed
CAUSE
A request is being processed in the vision system.
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
285 VS: Request cannot be finished and is being aborted
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
286 VS: Hardware error in vision system (FATAL ERROR)
CAUSE
Hardware error
REMEDY
If this error still occurs after numerous attempts, reset ICOS.
287 Coplanarity has received a hardware break
CAUSE
A hardware break was sent to the coplanarity module.
REMEDY
Hardware error: check coplanarity module; check M18; check supply voltage of the coplanarity mod-
ule.
288 Telegram to coplanarity has no STX
CAUSE
The first character sent to the coplanarity module is lost.
REMEDY
Check supply voltage; check jumper; repeat measurement.
289 Undefined error message
CAUSE
Should not occur.
REMEDY
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 31
290 Coplan.: Parameter number unknown
CAUSE
Should not occur.
REMEDY
291 Coplan.: Attempt to modify a Read Only Para
CAUSE
Should not occur
REMEDY
292 Communication to vision system defective (Error code -11)
CAUSE
System error
REMEDY
Reset system.
293 Communication to vision system defective (Error code -10)
CAUSE
System error
REMEDY
Reset system.
294 Communication to vision system defective (Error code -9)
CAUSE
System error
REMEDY
Reset system.
295 Communication to vision system defective (Error code -8)
CAUSE
System error
REMEDY
Reset system.
296 Communication to vision system defective (Error code -7)
CAUSE
System error
REMEDY
Reset system.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 32
297 Communication to vision system defective (Error code -6)
CAUSE
System error
REMEDY
Reset system.
298 Communication to vision system defective (Error code -5)
CAUSE
System error
REMEDY
Reset system.
299 Communication to vision system defective (Error code -4)
CAUSE
System error
REMEDY
Reset system.
300 Communication to vision system defective (Error code -3)
CAUSE
Timeout during request to vision system (MVS / M10000).
REMEDY
Reset vision system; at M10000 check V24 connection between MC and M10000.
301 Communication to vision system defective (Error code -2)
CAUSE
System error
REMEDY
Reset system.
302 Communication to vision system defective (Error code -1)
CAUSE
System error
REMEDY
Reset system.
303 Communication to vision system defective (Error code 0)
CAUSE
System error
REMEDY
Reset system.