SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 37 331 Measured va lue outside tol. (Error c ode 21H) CAUSE ● Error durin g course of me asurement …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 36
325 Measure ranges exceeded (Error code 1BH)
CAUSE
Setpoint specified is incorrect; incorrect component at the nozzle; mismeasurement (jaws dirty)
REMEDY
Check data record for CRDL test in the component description in the line computer and correct if
necessary; check components; clean jaws.
326 Measured value outside tol. (Error code 1CH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
327 Measured value outside tol. (Error code 1DH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
328 Measured value outside tol. (Error code 1EH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
329 Measured value outside tol. (Error code 1FH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 37
331 Measured value outside tol. (Error code 21H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
335 Measured value outside tol. (Error code 25H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
336 Measured value outside tol. (Error code 26H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 38
337 Measured value outside tol. (Error code 27H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
338 Measured value outside tol. (Error code 28H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
339 Measured value outside tol. (Error code 29H)
CAUSE
Component incorrect.
REMEDY
Check set-up.
340 Wrong diode polarity, check feeder (2AH)
CAUSE
Diode positioned incorrectly polarized between the measuring jaws.
REMEDY
341 Tantalum capacitor pol. not detected (2BH)
CAUSE
Component incorrect.
REMEDY
Check set-up.
342 Wrong tantal C pol., check feeder (2CH)
CAUSE
Capacitor positioned incorrectly polarized between the measuring jaws.
REMEDY
Not necessary since positioning corrected automatically.