19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 8 63 X axis disabled CAUSE ● x axis s witched o ff at the axis controlle r switch. REMEDY ● x axis…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 7
52 BERO SZ2 not being actuated
CAUSE
●
Bad plugged connection of the screwdriver at the gantry board; motor control board
defective.
REMEDY
●
Check plugged connections; fit new motor control board, carry out calibration of the axes.
53 SZ2 only succeeded on second attempt
CAUSE
●
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration of
the motor control board not optimal.
REMEDY
●
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
54 BERO SZ1 not being actuated
CAUSE
●
Bad plugged connection of the screwdriver at the gantry board; motor control board defective.
REMEDY
●
Check plugged connections; fit new motor control board, carry out calibration of the axes.
59 X axis does not reach setpoint position
CAUSE
●
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
●
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
60 Y axis does not reach setpoint position
CAUSE
●
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
●
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
61 Z axis does not reach setpoint position
CAUSE
●
Cam disk in incorrect position at zero pulse; motor defective; z axis jamming.
REMEDY
●
Fit cam disk in correct rotational position; redetermine zero point correction; replace motor; carry out
axis calibration; fit spare placement head.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 8
63 X axis disabled
CAUSE
●
x axis switched off at the axis controller switch.
REMEDY
●
x axis should be switched on at the axis controller switch.
64 Y axis disabled
CAUSE
●
y axis switched off at the axis controller switch.
REMEDY
●
y axis should be switched on at the axis controller switch.
65 D1 axis disabled
CAUSE
●
dp1 axis switched off at the axis controller switch.
REMEDY
●
dp1 axis should be switched on at the axis controller switch.
66 D2 axis disabled
CAUSE
●
dp2 axis switched off at the axis controller switch.
REMEDY
●
dp2 axis should be switched on at the axis controller switch.
67 Star axis disabled
CAUSE
●
Star axis switched off at the axis controller switch.
REMEDY
●
Star axis should be switched on at the axis controller switch.
68 Z axis disabled
CAUSE
●
z axis switched off at the axis controller switch.
REMEDY
●
z axis should be switched on at the axis controller switch.
75 Programmed position of Z axis outside travel range
CAUSE
●
Machine data in the line computer erroneous; height reference run is not carried out on the PCB
conveyor.
REMEDY
●
Check the machine data in the line computer.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 9
79 Arm for turning station 1 has not swivelled out
CAUSE
●
Feed motor defective; proximity switch defective.
REMEDY
●
Replace feed motor; carry out axis calibration; fit new proximity switch.
80 Arm for turning station 2 has not swivelled out
CAUSE
●
Feed motor defective; proximity switch defective.
REMEDY
●
Replace feed motor; carry out axis calibration; fit new proximity switch.
94 DETERMINANT not correct during position recognition
CAUSE
●
The two fiducials of a circuit image are on one position; the three fiducials of a circuit image are in a
line.
REMEDY
●
Correct placement program in the line computer.
95 Fiducial missing in position recognition
CAUSE
●
Fiducial quality of a fiducial not adequate; PCB transport adjusted imprecisely; camera illumination
defective; search field too small.
REMEDY
●
Clean fiducial; reteach fiducial (increase size of search field); check conveyor width; check stopper
setting.
96 CORR_MOVE not correct during position recognition
CAUSE
●
The two fiducials of a circuit image are on one position.
REMEDY
●
Correct placement program in the line computer.
101 Track empty, no component during pick-up
CAUSE
●
On a single track at least three pick-up errors occurred immediately after one another; no compo-
nent in the pick-up position; set up for incorrect component (e.g. cubic instead of non-cubic).
feeder jamming; cover foil parted.
REMEDY
●
Refill components and reset track; check set-up.
get feeder working properly again.