19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 52 431 Colinearity: no res ult CAUSE ● Due to a pr eceding error no result is issued by the visi o…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 51
425 No. of pins: Evaluation not possible
CAUSE
●
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
●
Optimize pick-up; check charge (component).
426 Colinearity: Evaluation not possible
CAUSE
●
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
●
Optimize pick-up; check charge (component).
427 Spacing: Evaluation not possible
CAUSE
●
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
●
Optimize pick-up; check charge (component).
428 Position: no result
CAUSE
●
Due to a preceding error no result is issued by the vision system.
REMEDY
●
See preceding error.
429 Dimension: no result
CAUSE
●
Due to a preceding error no result is issued by the vision system.
REMEDY
●
See preceding error.
430 No. of pins: no result
CAUSE
●
Due to a preceding error no result is issued by the vision system.
REMEDY
●
See preceding error.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 52
431 Colinearity: no result
CAUSE
●
Due to a preceding error no result is issued by the vision system.
REMEDY
●
See preceding error.
432 Spacing: no result
CAUSE
●
Due to a preceding error no result is issued by the vision system.
REMEDY
●
See preceding error.
433 Position: Component outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 53
438 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
439 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
440 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
441 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
442 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
443 Coplan.: Measuring data buffer is full
CAUSE
●
Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
●
Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
444 Undefined error message
CAUSE
●
Does not occur
REMEDY
●