00191025-01.pdf - 第714页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 27 1134 X-axis error: Referenc e point not found CAUSE ● Referen ce point not fo und on sc ale; s…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 126
1127 X-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1128 Y-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1129 xk-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1130 yk-axis error: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1131 Z-axis error, GU1: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1132 Z-axis error; GU2: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1133 Z-axis error; GU3: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 127
1134 X-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1135 Y-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1136 xk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1137 yk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1138 Z-axis error, GU1: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1139 Z-axis error; GU2: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1140 Z-axis error; GU3: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 128
1141 X-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1142 Y-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1143 xk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1144 yk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1145 Z-axis error, GU1: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1146 Z-axis error; GU2: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1147 Z-axis error; GU3: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism