00191025-01.pdf - 第620页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 33 304 Communication to vision system defective (Error code 1) CAUSE ● System error REMEDY ● Reset …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 32
297 Communication to vision system defective (Error code -6)
CAUSE
System error
REMEDY
Reset system.
298 Communication to vision system defective (Error code -5)
CAUSE
System error
REMEDY
Reset system.
299 Communication to vision system defective (Error code -4)
CAUSE
System error
REMEDY
Reset system.
300 Communication to vision system defective (Error code -3)
CAUSE
Timeout during request to vision system (MVS / M10000).
REMEDY
Reset vision system; at M10000 check V24 connection between MC and M10000.
301 Communication to vision system defective (Error code -2)
CAUSE
System error
REMEDY
Reset system.
302 Communication to vision system defective (Error code -1)
CAUSE
System error
REMEDY
Reset system.
303 Communication to vision system defective (Error code 0)
CAUSE
System error
REMEDY
Reset system.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 33
304 Communication to vision system defective (Error code 1)
CAUSE
System error
REMEDY
Reset system.
305 Undefined error number from CRDL (0C)
CAUSE
Should not occur.
REMEDY
306 Undefined error number from CRDL (0D)
CAUSE
Should not occur.
REMEDY
307 Undefined error number from CRDL (0E)
CAUSE
Should not occur.
REMEDY
308 Undefined error number from CRDL (0F)
CAUSE
Should not occur.
REMEDY
309 Undefined error number from CRDL (10)
CAUSE
Should not occur.
REMEDY
310 Undefined error number from trolley (E0)
CAUSE
Should not occur.
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 34
311 Undefined error number from vision system (FD)
CAUSE
System error
REMEDY
Reset system.
312 Coplan.: Component description has too many groups
CAUSE
Package form data erroneous.
REMEDY
Check package form data and respecify set-up.
313 Coplan.: Component number invalid
CAUSE
No component description exists for the component to be measured
REMEDY
Check set-up and respecify.
314 CRDL not initialized, test not possible
CAUSE
Incorrect command sent to tester.
REMEDY
If electrical testing is not possible, reset tester.
315 CRDL internal error (Error code 11H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
316 CRDL internal error (Error code 12H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
317 CRDL internal error (Error code 13H)
CAUSE
Hardware error at tester.
REMEDY
Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.