SIPLACE 80S/F/G User’s Manual 3 Switching On Edition 12/96 from S oftware Version SR.009.xx 3.2 Operator Actions During Switching-On 3 - 5 3.2 Operator Actions During Switching-On 3.2.1 Preconditions for switching on ● C…

100%1 / 736
3 Switching On SIPLACE 80S/F/G User’s Manual
3.1 Introduction: Switching On Edition 12/96 from Software Version SR.009.xx
3 - 4
Fig. 3.1.1 Flow diagram: switching on
Without
line computer:
input set-up and cluster
Data conversion
if applic. adapt nozzles
With
line computer:
set-up and cluster from LC
Functional sequence
of the reference point run
Press START button
Screen message:
Wait for reference run
If
no
line computer
selection "with" or "without" LC
Station software starts
initialization of the MCs
Start station software
Switch placement machine on
at the main switch
Pre-start check of the placement machine
Placement (Section 5)
SIPLACE 80S/F/G User’s Manual 3 Switching On
Edition 12/96 from Software Version SR.009.xx 3.2 Operator Actions During Switching-On
3 - 5
3.2 Operator Actions During Switching-On
3.2.1 Preconditions for switching on
Check whether the power and compressed air supplies of the placement machine are connected.
Conduct a visual inspection of the placement machine. Here make sure in particular that there are no
obstacles in the travel range of the gantry axes.
Close the protective covers.
Make sure that there is
no
system diskette in the floppy drive.
The placement machine may only load the
RMOS
operating system installed on the hard disk.
3.2.2 Switching on
Switch on the machine at the main switch.
The placement machine software is loaded (system start). The machine controllers are initialized with the
machine data held on the hard disk.
During initialization of the machine controllers there appears on the screen the following display.
Fig. 3.2.1
SIPLACE 80 V 9.x
Cluster:
Set-up:
Component feeding Display errors
Confirm errors
Machine options
Error
State
Action
:
:
:
Waiting for data
3 Switching On SIPLACE 80S/F/G User’s Manual
3.2 Operator Actions During Switching-On Edition 12/96 from Software Version SR.009.xx
3 - 6
3.2.3 Line computer mode
If a line computer is connected, the following menu will be ignored. The screen menu appears only briefly and
the system starts up independently (see Section 3.2.4). It is not possible to choose whether placement takes
place with or without line computer.
If no line computer is connected or communication is interrupted, the menu "LC mode" appears.
NOTE
If the line computer is "shut down", when the line is run up the stations must be rebooted as well.
Fig. 3.2.2
At this point correct any communications fault which may have occurred with the line computer or connect a
line computer up to the station.
Position the cursor bar with the aid of the
cursor keys
over the menu item "With LC".
Press the
return
key.
In this mode the placement machine is supplied by the line computer with the data necessary for place-
ment.
SIPLACE 80 V 9.x
Cluster:
Rüstung :
Component feeding Display errors
Confirm errors
Machine options
Error
State
Action
:
:
:
Softwareoptionen
Masch.Fehler anz.
LC mode
with LC
without LC
Wait for data