00191025-01.pdf - 第596页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 9 79 Arm for tur ning station 1 has not swivelled out CAUSE ● Feed m otor defec tive; prox imity s …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 8
63 X axis disabled
CAUSE
x axis switched off at the axis controller switch.
REMEDY
x axis should be switched on at the axis controller switch.
64 Y axis disabled
CAUSE
y axis switched off at the axis controller switch.
REMEDY
y axis should be switched on at the axis controller switch.
65 D1 axis disabled
CAUSE
dp1 axis switched off at the axis controller switch.
REMEDY
dp1 axis should be switched on at the axis controller switch.
66 D2 axis disabled
CAUSE
dp2 axis switched off at the axis controller switch.
REMEDY
dp2 axis should be switched on at the axis controller switch.
67 Star axis disabled
CAUSE
Star axis switched off at the axis controller switch.
REMEDY
Star axis should be switched on at the axis controller switch.
68 Z axis disabled
CAUSE
z axis switched off at the axis controller switch.
REMEDY
z axis should be switched on at the axis controller switch.
75 Programmed position of Z axis outside travel range
CAUSE
Machine data in the line computer erroneous; height reference run is not carried out on the PCB
conveyor.
REMEDY
Check the machine data in the line computer.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 9
79 Arm for turning station 1 has not swivelled out
CAUSE
Feed motor defective; proximity switch defective.
REMEDY
Replace feed motor; carry out axis calibration; fit new proximity switch.
80 Arm for turning station 2 has not swivelled out
CAUSE
Feed motor defective; proximity switch defective.
REMEDY
Replace feed motor; carry out axis calibration; fit new proximity switch.
94 DETERMINANT not correct during position recognition
CAUSE
The two fiducials of a circuit image are on one position; the three fiducials of a circuit image are in a
line.
REMEDY
Correct placement program in the line computer.
95 Fiducial missing in position recognition
CAUSE
Fiducial quality of a fiducial not adequate; PCB transport adjusted imprecisely; camera illumination
defective; search field too small.
REMEDY
Clean fiducial; reteach fiducial (increase size of search field); check conveyor width; check stopper
setting.
96 CORR_MOVE not correct during position recognition
CAUSE
The two fiducials of a circuit image are on one position.
REMEDY
Correct placement program in the line computer.
101 Track empty, no component during pick-up
CAUSE
On a single track at least three pick-up errors occurred immediately after one another; no compo-
nent in the pick-up position; set up for incorrect component (e.g. cubic instead of non-cubic).
feeder jamming; cover foil parted.
REMEDY
Refill components and reset track; check set-up.
get feeder working properly again.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 10
102 Quality too low during optical centering
CAUSE
Parameters for optical centering erroneous.
REMEDY
Check the package form in the components manipulator.
103 Spacing of a pin group out of tolerance
CAUSE
Bent terminal pin; pitch error limit defined too small.
REMEDY
Check components; increase pitch error limit in the package form editor.
104 Component angle outside of tolerance
CAUSE
Angular positioning deviation of the component on the nozzle too great; angular positioning toler-
ance defined too small.
REMEDY
Improve pick-up; increase angular positioning tolerance.
121 Peak offset: no result
CAUSE
Component terminal pin bent.
REMEDY
Check quality of the components.
122 Coplanarity module cannot be initialized
CAUSE
Coplanarity module not plugged in; configuration jumper incorrectly set
REMEDY
Plug in module; correct jumper.
123 Coplan.: Data value outside of range
CAUSE
Error in cluster or set-up: PF file faulty
REMEDY
Check data for coplanarity in cluster and set-up; check PF data.
124 Vacuum reduction at placem. stat. too slow
CAUSE
During placement of a component the vacuum does not reduce fast enough;
forced air not present; forced air defective.
REMEDY
Check forced air; check forced air valve.