Fig.130: Open Door
► Open the door(1) once the lift has
reached the refill position.
► Press the spring(2) down and pull the
cassette out on the rails.
Fig.131: Take Off Cassette
► Secure the trays with the transportation
lock and the direction lock.
► Lift off the cassette from the rails. Hold
the cassette horizontal and place it on
a stable surface.

5 Tasks on the machine
5.2 Task: Operating the feeder
User Manual / Bedienungsanleitung / 用户手册 SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019 165
5.2.5 Inserting the cassette into the SIPLACE JTF-ML2
Fig.132: Moving the cassette into the refill position
► Click Refill position and Quit refill
position.
Fig.133: Inserting the cassette
CAUTION!
Avoiding component jump
Improper or sudden inserting of the
cassettes may lead to component
jump.
Always keep the cassette horizontal
when lifting and holding.
.
► Open the door(1).
► Place the cassette on the rails(2) on
the inner side of the door.
Observe the orientation. The spring(3)
must point outwards.

5 Tasks on the machine
5.2 Task: Operating the feeder
166 User Manual / Bedienungsanleitung / 用户手册 SIPLACE TX V1/V2 Series JEDEC Tray Feeder (JTF-ML2) 11/2019
Fig.134: Unlocking the transportation lock
► Unlock the transportation lock.
► Ensure the direction lock is in position
"open".
Fig.135: Inserting the cassette
► Press down the spring(1) completely.
► Carefully push(2) the cassette into the
tower.
Avoid sudden movement to avoid
component jump.
► Release the spring(3).
► Close the door.
Fig.136: Moving the cassette into the refill position
► Click Refill position and Quit refill
position.
ð The SIPLACE JTF‑ML2 is ready for
operation again.