00197725-12_GS_SE3.11_EN.pdf - 第98页
4 SIPLACE Explorer Factory Configuratio n Utility Getting Started SIPLACE Explorer Edition 11/2020 EN from 3.11 (R20-2) 98 4.9 How T o Use the Factory W ebsite The facto ry website is the so-ca lled "Single Entry Po…

Getting Started SIPLACE Explorer 4 SIPLACE Explorer Factory Configuration Utility
from 3.11 (R20-2) Edition 11/2020 EN
97
4.8.1.5 Websites Clean-up Options
This is where you can define the properties of the clean-up options for line websites and factory
websites. 4
Select Websites clean-up ... from the File menu.
4
Fig. 4 - 25 Factory configuration utility - websites clean-up
Enable the necessary options.
Check your entries and confirm with OK.
4.8.1.6 Language
The language for the Factory Configuration Utility can be set here. 4
In the File menu, select Language...
4
Fig. 4 - 26 Factory configuration utility - select language
Select the required language and confirm your choice with OK.
4.8.2 Menu Scheduler
To generate the configured factory reports, start the scheduler here. You have already defined the
generation of the factory reports in the Reports tab, see ”Reports”, page - 85. When started, the
scheduler automatically creates a scheduled task. This scheduled task instructs the system to
read factory report data out of the line databases and to create factory reports in the form of Excel
files. 4
In the Scheduler menu, select Start Scheduler... or click on the Start Scheduler icon.
Generation of the specified report will begin. The Start Scheduler icon in the toolbar will
change to Stop Scheduler .
4 SIPLACE Explorer Factory Configuration Utility Getting Started SIPLACE Explorer
Edition 11/2020 EN from 3.11 (R20-2)
98
4.9 How To Use the Factory Website
The factory website is the so-called "Single Entry Point" for all production line websites. This
means that you can navigate directly from the factory website to all other production line websites
which have been configured with the Factory Configuration Utility. 4
The following tabs can be accessed via the Factory Website: 4
– Factory Website - Overview Tab
Using the main page as the "Single Entry Point" for production line websites
– Factory Website - Reports Tab
Defining reports to specify when and what to generate and how often.
– Factory Website - Consumption Tab
Overview of the component consumption data. Users can choose to view all lines or one
specific line.
– Factory Website - Configuration Tab
Shows addition or removal of a production line / station.
For stations with station software version SW 703, stations or placement heads are shown if
they are set in SIPLACE Pro to the "PCB bypass" mode.
For SIPLACE SX machines addition or removal of the gantry is shown.
4.9.1 How to Start the Factory Website
Start the Microsoft Internet Explorer. Enter the HTTP address of the factory website in the
Address field.
The login page will open.
For a detailed description, please refer to SIPLACE Explorer SMA User Guide. 4
4

Getting Started SIPLACE Explorer Annex
Edition 11/2020 EN Recording Data with Backflush
99
Annex
Recording Data with Backflush
Consumption data can be recorded with Backflush. This data can be generated for a time period,
for a machine/board and/or per day. 4
Additionally, you can record the downloaded recipes and the E10 state. 4
Backflush generates the recording as an xml file. The target folder for this xml file can be specified
as required. 4
The recording settings are defined in the Line Configuration function. For a detailed description
of these settings, please see Section “Step 6 - Modify Application Parameters” on page 45. 4
ATTENTION
The files generated by Backflush are not managed with Backflush To avoid overloading your hard
drive, you will need to archive or delete these files as individually required. 4
NOTE
The system performance of SIPLACE Explorer is reduced if the option MS-DOS-Readable File
Name is enabled in the operating system. This option stores more than 300000 files in the target
folder. If SIPLACE Explorer needs to process many boards, the number of files stored in the target
folder might even exceed 500000, which significantly reduces the system performance of
SIPLACE Explorer.
To prevent this, archive or delete the data from the target folder at regular intervals.
We also recommend that you disable the MS-DOS-Readable File Name option for the operating
system. Please contact your system administrator.
If the MS-DOS-Readable File Name option for the operating system is disabled, the number of
files in the target folder will have no effect on the system performance of SIPLACE Explorer, even
of the volume of files exceeds 1000000. 4