3 Technical data and assemblies I nstruction manual SIPLACE CA4 V 2 3.2 Ambient conditions and connecti on values From software versi on 713.0 Edition 12/2019 100 3.2 Ambient conditions and connection values 3.2.1 Ambien…

100%1 / 322
Instruction manual SIPLACE CA4 V2 3 Technical data and assemblies
From software version 713.0 Edition 12/2019 3.1 Placement performance and accuracy
99
3.1.4 Configuration overview
3
3.1.5 Component supply
3
Head configurations
Placement head
types
SIPLACE SpeedStar (C&P20 M2)
SIPLACE MultiStar (CPP M)
Placement area 1 Placement area 2
C&P20 M2 C&P20 M2 C&P20 M2 C&P20 M2
C&P20 M2 C&P20 M2 CPP M CPP M
CPP M CPP M CPP M CPP M
Configurations/options C&P20 M2 CPP M
SWS Flip-Chip X X
*a
*)a Collect&Place mode only
SWS Die Attach X X
*b
*)b 6 magazines with 72 nozzle garages
LDU X on X table X X
LDU 2X on X table X X
LDU X on SWS X X
Nozzle changer X
*b
X
Nozzle changer, "row 2" X X
JTF-S/JTF-M X X
SIPLACE Glue Feeder X X
Component camera, type 45 -- X
Component camera, type 48 X --
Component camera, type 49 X --
PCB camera, type 34 X X
Single lane conveyor X X
Dual lane conveyor X X
Panel lane conveyor X X
Wafer lane conveyor X X
Tape reel diameter
Standard
Maximum
to 432 mm (17")
483 mm (19")
Max. component supply
4 component trolley X
160 feeder modules, each with 8 mm X
Component trolley changeover time < 1 minute
Feeder module types (SIPLACE X) with adapter
Roadrunner, S linear vibratory feeder and label presenter
3 Technical data and assemblies Instruction manual SIPLACE CA4 V2
3.2 Ambient conditions and connection values From software version 713.0 Edition 12/2019
100
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Ambient conditions for placement machine operation
3
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between + 15°C and + 35°C
Atmospheric humidity 30% to 75%
(on average not higher than 45%, so that there is no risk of
condensation on the placement machine.)
Ambient pressure > 750 mbar (corresponds to 1700 m above mean sea level)
Instruction manual SIPLACE CA4 V2 3 Technical data and assemblies
From software version 713.0 Edition 12/2019 3.2 Ambient conditions and connection values
101
3.2.3 Electrical ratings and energy consumption
3
3
PLEASE NOTE
Use of a residual current protection device
The low ground leakage current of the system makes it possible to use an upstream
residual current protection device at the customer end. This must be all-current sen-
sitive (RCD type B).
SIPLACE CA4 V2
Electrical ratings
Supply voltage Fuse
Mains power supply 3 x 380 V~ to 3 x 415 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60 Hz
*a
3 x 16A characteristic C
3 x 15A characteristic C
*b
Mains power con-
nection
Without cable
Cable 5 x 4 mm² WITH CEE plug, red 16 A (in accordance with IEC 60309)
(3 x 380 V~ to 3 x 415 V~)
Cable 5 x 4 mm² WITHOUT plug (3 x 200 V~ to 3 x 220 V) or (3 x 380 V~ to 3 x 415 V~)
Short circuit rating (SCCR)
*c
10 kA
Energy consumption
With a vacuum pump
*d
With two vacuum pumps *
b
Without vacuum pumps
*e
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
*)a With options package
*)b e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)c With the original mains connection cable. The short-circuit rating (SCCR) relates to the beginning of the original mains cable.
If changes are conducted at the customer site, the factory-set length of the mains supply cable to the placement machine may
not be shortened nor the factory-set wire cross-section increased, as this would worsen the short-circuit rating (SCCR).
*)d Vacuum pump for C&P20 M2 head only.
*)e Optional