00198382-03_UM_SIPLACE-CA4-V2_EN.pdf - 第295页

Instruction manual SIPLACE CA4 V2 7 Station extensions From software version 713.0 Ed ition 12/2019 7.3 SIPLACE Waf er Sys tem (SWS) 295 7.3 SIPLACE W afer System (SWS) The SIPLACE CA4 V2 facilit ates operation with the …

100%1 / 322
7 Station extensions Instruction manual SIPLACE CA4 V2
7.2 Vacuum pump From software version 713.0 Edition 12/2019
294
7.2.2 Safety instructions for vacuum pumps
All the following measures are to be observed during service work to the vacuum pumps:
Service work may only be performed by trained service personnel
Both the main switch for the placement machine and the main switch for the vacuum tooling
vacuum pump (item 2 in the fig. 7.2 - 1
, page 293) are to be secured in the OFF position with
a padlock, to prevent unauthorized activation.
Both the CEE connector for the SIPLACE CA4 V2 and the CEE connector for the vacuum
pump of the vacuum tooling are to be unplugged from the mains supply.
Unplug the connector for the motor cable (ILME connector) at all three vacuum pumps. These
connectors are at a maximum of 1.6m away from the pumps and are therefore visible to the
service engineer.
7
7.2.3 Description
Each Collect&Place head has its own vacuum generator, which supplies the holding and place-
ment circuit with the required vacuum. The vacuum generator for the placement heads functions
according to the Venturi principle. When operated together with a vacuum pump, the compressed
air consumption for the SpeedStar (C&P20 M2) head can be reduced considerably. A vacuum
pump can supply up to two SpeedStar (C&P20 M2) heads. A maximum of two vacuum pumps can
therefore be used (for 4x C&P20 M2). The running costs will fall according to the energy costs
incurred.
The vacuum pump is switched on and off with the placement machine. The station software auto-
matically takes a runoff time of 6 minutes into consideration at switch off.
7
7.2.4 Maintenance instructions
Observe the additional maintenance instructions for the vacuum pump.
Read the relevant section in the maintenance manual for your placement machine.
WARNING
Please observe the safety instructions in the manufacturer's instruction manual sup-
plied.
PLEASE NOTE
The compressed air consumption values can be found in section 3.2.4
, page 102.
Instruction manual SIPLACE CA4 V2 7 Station extensions
From software version 713.0 Edition 12/2019 7.3 SIPLACE Wafer System (SWS)
295
7.3 SIPLACE Wafer System (SWS)
The SIPLACE CA4 V2 facilitates operation with the SIPLACE Wafer System (SWS).
The placement machine can be fitted with an SWS at each location, so that so-called dies can be
placed from wafers. Only the innermost table position is possible at locations 2 and 4. This makes
the components (dies) directly available to the placement head, in wafers. Up to four SIPLACE
Wafer Systems (SWS) can be used at the SIPLACE CA4 V2. The SIPLACE CA4 V2 can also be
operated without an SWS and with four changeover tables at the locations.
To ensure access to the installed SWS in the placement machine, a sliding door has been fitted
to the side of each placement machine location.
See also the user guide for the SIPLACE Wafer Feeder (SWS).
7
Fig. 7.3 - 1 SIPLACE CA4 V2 placement machine with one SIPLACE Wafer System (SWS)
(1) SIPLACE CA4 V2
(2) SIPLACE Wafer System (SWS) at location 2
(3) Side sliding doors
(T) Direction of PCB conveyor
(1)
(2)
(3)
7 Station extensions Instruction manual SIPLACE CA4 V2
7.4 Sensor for the component reject bin From software version 713.0 Edition 12/2019
296
7.4 Sensor for the component reject bin
[00116848-xx] Query component reject bin X-Series/D3
The sensor for the component reject bin monitors whether the reject bin is seated correctly in its
mount.
If the reject bin was not inserted correctly, the placement machine cannot be started.
If the reject bin jumps out of its mount during the placement process, the placement machine
will be stopped immediately to avoid a head crash.
Each reject bin can be monitored by a separate sensor.
7
PLEASE NOTE
When using a SIPLACE SpeedStar (C&P20 M2) at a location without SWS, we recom-
mend that you install the optional sensor for the component reject bin.