00198382-03_UM_SIPLACE-CA4-V2_EN.pdf - 第182页
4 Setting up and commissioning Instruction manual SIPLACE CA4 V2 4.3 Setting up the placement mac hine From software versio n 713.0 Edition 12/2019 182 4.3.8.2 Aligning the placement machine with the air cushio n tran sp…

Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.3 Setting up the placement machine
181
4
Fig. 4.3 - 12 Aligning and locking the middle machine feet
Use the spirit level to ensure that the placement machine is precisely aligned.
Use the fork wrench SW65 to tighten the lock nut M24 (item 3).
(1) Spacer
(2) Middle machine foot
(3) Lock nut M24

4 Setting up and commissioning Instruction manual SIPLACE CA4 V2
4.3 Setting up the placement machine From software version 713.0 Edition 12/2019
182
4.3.8.2 Aligning the placement machine with the air cushion transport system
Place the four air cushions from the air cushion conveyor system under the contact points on
the machine frame.
Raise the placement machine and align it with respect to the line.
Check the distance from the PCB conveyor system of the adjacent placement machine. It
should be between 1 mm and 3 mm.
Lower the placement machine.
4
Fig. 4.3 - 13 Contact surfaces for the air cushion conveyor system
(1) 4 contact points for the air cushion conveyor system
(1)
(1)

Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.3 Setting up the placement machine
183
4.3.8.3 Fitting the floor brace (optional)
The placement machine can be secured against sliding in the event of strong vibrations (e.g.
earthquakes) with a floor brace, if required.
Fit a floor brace to each machine foot.
4
Fig. 4.3 - 14 Floor brace
Place the floor brace (1) over the machine foot.
Attach the floor brace to the floor with suitable fixtures, at the six holes (2) provided.
4.3.9 Removing the shipping braces
The shipping braces are attached to the linear guides. Each gantry is fastened with two shipping
braces on the X and Y axes.
Remove all the shipping braces from the gantry axes.
If the SIPLACE placement machine needs to be transported, always fit the shipping braces
back onto the conveyor.
4.3.10 Removing the corrosion protection from the guide rails
The placement machines were given a corrosion protection treatment before they were delivered.
(2)