00198382-03_UM_SIPLACE-CA4-V2_EN.pdf - 第166页
4 Setting up and commissioning Instruction manual SIPLACE CA4 V2 4.3 Setting up the placement mac hine From software versio n 713.0 Edition 12/2019 166 4.3.3 Fitting att ached p art s The placement machine is delivered w…

Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.3 Setting up the placement machine
165
4
4
4
4
WARNING
Risk of damage due to excessive fork spacing!
Increased fork spacing, which means that the placement machine is raised at points out-
side its contact surface, can lead to deformation of the placement machine frame and
cause damage to cables and lines.
The forks may only be opened to a degree which ensures that they are still within
the contact area of the machine underside (see fig. 4.1 - 3
, page 149).
WARNING
Risk of damage due to one-sided loading!
One-sided loading of the machine feet e.g. from tilting the machine, can lead to deforma-
tion of the machine feet fixtures.
Make sure that the forks are evenly loaded when you lift the placement machine.
Use a firm support layer between the forks and the placement machine.
Enlist the help of a second person to watch while you lift the placement machine and
make sure that the placement machine does not tip over to one side.
WARNING
Risk of damage!
The thread for the machine feet in the machine frame could be damaged by being
dragged along the floor or from impact.
When you are transporting the machine, make sure that all the feet are clear of the
floor.
WARNING
Risk of damaging the exhaust air duct for the vacuum pump!
Vacuum pumps can be fitted in placement area 1. The exhaust air duct is fitted under the
machine base. This exhaust air duct could be damaged during transportation with the
fork-lift.
Dismantle the exhaust air duct before you transport the placement machine with the
fork-lift.

4 Setting up and commissioning Instruction manual SIPLACE CA4 V2
4.3 Setting up the placement machine From software version 713.0 Edition 12/2019
166
4.3.3 Fitting attached parts
The placement machine is delivered with the monitor, keyboard and indicator lamp dismantled. To
fit these components, proceed as follows:
– To fit the indicator lamps,see section 4.3.3.2
, page 166
– To fit the monitor see section 4.3.3.3, page 4.3.3.3
– Hook up the keyboard fixture and connect the keyboard (optional)
4.3.3.1 Checking and setting the protective cover switch
Check the function of the protective cover switch (see 2.5.1, page 63).
Adjust the protective cover switch if necessary (see service manual).
4.3.3.2 Fit the indicator lamp
Insert the indicator lamp into the hole until the lamp tube projects sufficiently into the terminal
beneath.
Connect the cable for the indicator lamps to the connector. The cable with connector is lo-
cated in the tube.
Tighten the two screws on the terminal so that the indicator lamp is clamped into place.
4.3.3.3 Fit the monitors
Use the 4 fastening screws to fix the monitor to the monitor mount and then connect the cable.
Check the cable connections.

Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.3 Setting up the placement machine
167
4.3.4 PCB conveyor height on the placement machine
The placement machine can be set to the following PCB conveyor heights:
900 mm ± 15 mm 4
930 mm ± 15 mm (standard height) 4
950 mm ± 15 mm (SMEMA height) 4
4
4.3.5 Tools and equipment
You will need the following tools and equipment to adjust the height of your placement machine:
– Fork wrench SW 36, Item no. 00096286-01
– Wrench of width 36 for the setting screw M24x2x120 used to adjust the height of the machine
feet.
– Hook wrench 135 - 145 for adjusting the middle machine feet,
Item no. 00376519-xx
– Single head wrench SW 65, Item no. 00353827-0, width 65 for the hexagonal lock nut M24
on the middle machine foot
– Allen wrench, size 10, Item no. 00373926-01 for hexagon socket-head screws M12x80 for
fastening the spacers on the middle machine feet
– Allen wrench, size 19, Item no. 00373928-01 for hexagon socket-head screw M24x90 for
temporary fixture of clamping pieces for the four outer machine feet
– Torque wrench with hexagonal pin, size 19, tightening torque 130 Nm
for final fastening of four outer machine feet
– Machine spirit level: accuracy 0.02 mm/m
– Fork lift truck (specification see 4.1.4.3 on page 146).
– Air cushion conveyor system: SIPLACE HSxx, Item No. 00119002-S01 (optional)
PLEASE NOTE
The PCB conveyor height is the distance between the top edge of the PCB conveyor belt
and the bottom edge of the machine feet.