00198382-03_UM_SIPLACE-CA4-V2_EN.pdf - 第102页

3 Technical data and assemblies I nstruction manual SIPLACE CA4 V 2 3.2 Ambient conditions and connecti on values From software versi on 713.0 Edition 12/2019 102 3.2.4 Compressed air supply and compressed air specificat…

100%1 / 322
Instruction manual SIPLACE CA4 V2 3 Technical data and assemblies
From software version 713.0 Edition 12/2019 3.2 Ambient conditions and connection values
101
3.2.3 Electrical ratings and energy consumption
3
3
PLEASE NOTE
Use of a residual current protection device
The low ground leakage current of the system makes it possible to use an upstream
residual current protection device at the customer end. This must be all-current sen-
sitive (RCD type B).
SIPLACE CA4 V2
Electrical ratings
Supply voltage Fuse
Mains power supply 3 x 380 V~ to 3 x 415 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60 Hz
*a
3 x 16A characteristic C
3 x 15A characteristic C
*b
Mains power con-
nection
Without cable
Cable 5 x 4 mm² WITH CEE plug, red 16 A (in accordance with IEC 60309)
(3 x 380 V~ to 3 x 415 V~)
Cable 5 x 4 mm² WITHOUT plug (3 x 200 V~ to 3 x 220 V) or (3 x 380 V~ to 3 x 415 V~)
Short circuit rating (SCCR)
*c
10 kA
Energy consumption
With a vacuum pump
*d
With two vacuum pumps *
b
Without vacuum pumps
*e
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
*)a With options package
*)b e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)c With the original mains connection cable. The short-circuit rating (SCCR) relates to the beginning of the original mains cable.
If changes are conducted at the customer site, the factory-set length of the mains supply cable to the placement machine may
not be shortened nor the factory-set wire cross-section increased, as this would worsen the short-circuit rating (SCCR).
*)d Vacuum pump for C&P20 M2 head only.
*)e Optional
3 Technical data and assemblies Instruction manual SIPLACE CA4 V2
3.2 Ambient conditions and connection values From software version 713.0 Edition 12/2019
102
3.2.4 Compressed air supply and compressed air specification
3
Compressed air supply
Compressed air pressure val-
ues
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" inner thread (pipe thread) with 1/2" hose connection
C o m p re ssed air con sum ption
*a
    Compressed air
consumption
*b
with vacuum pump
Compressed air con-
sumption
without vacuum
pump
*c
SIPLACE CA4 V2 C&P20 M2/&P20 M2/&P20 M2/&P20 M2
C&P20 M2/C&P20 M2/CPP M/CPP M
CPP M/CPP M/CPP M/CPP M
260 Nl/min
370 Nl/min
480 Nl/min
990 Nl/min
720 Nl/min
480 Nl/min
C o m p re ssed air sp ecification
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint + 3°
*)   .
*)      20 101 .
*)c Optional
Instruction manual SIPLACE CA4 V2 3 Technical data and assemblies
From software version 713.0 Edition 12/2019 3.3 Dimensions and weight
103
3.3 Dimensions and weight
3.3.1 Technical data - dimensions and weight
3
Length
*a
With handles for side sliding doors
1950 mm
2100 mm
Width
Outer contour of machine protection
With 2x SWS
On the component trolley and table position "outermost" (handle folded in)
On the component trolley and table position "outermost" (handle folded out)
2740 mm
4078 mm
2890 mm
3640 mm
Height of placement machine (for PCB conveyor height 930 mm)
Up to upper edge of monitor
With 2-color indicator lamp
With 3-color indicator lamp
Without indicator lamp (height of packaging)
With opened protective cover
With opened side sliding doors
1572 mm
1794 mm
1835 mm
1600 mm
2095 mm
2105 mm
Floor clearance of placement machine
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
195 mm ± 15 mm
225 mm ± 15 mm
245 mm ± 15 mm
Weight
SIPLACE CA4 V2 (placement machine without component trolley)
SIPLACE CA4 V2 (placement machine with 2x SWS)
SIPLACE CA4 V2 (placement machine with 4x SWS)
Changeover table (X)
Changeover table (X), fully configured with feeder modules
3674 kg
4374 kg
5074 kg
95 kg
190 kg
Location
*b
5.73 m²
Load per unit area
*c
With 4 component trolley X
With 4 SWS
6.1 kN/m²
6.88 kN/m²
Number of machine feet 6
*)a Measured at the outer contour of the machine protection.
*)b Measured at the outer contour of the machine protection and at the keyboard.
*)c The load per unit area calculation included an additional working space of 0.5 m on each side of the machine.